Hitachi SJ700 Series Manual page 20

Variable frequency drive
Hide thumbs Also See for SJ700 Series:
Table of Contents

Advertisement

●C GROUP: INTELLIGENT TERMINAL FUNCTIONS
Code
Function Name
C030
Digital current monitor reference value
C031
Terminal (11) active state
C032
Terminal (12) active state
C033
Terminal (13) active state
C034
Terminal (14) active state
C035
Terminal (15) active state
C036
Alarm relay terminal active state
C038
Low-current indication signal output mode selection
C039
Low-current indication signal detection level
C040
Overload signal output mode
C041
Overload level setting
C042
Frequency arrival setting for accel.
C043
Frequency arrival setting for decel.
C044
PID deviation level setting
C045
Frequency arrival setting for acceleration (2)
C046
Frequency arrival setting for deceleration (2)
C052
Maximum PID feedback data
C053
Minimum PID feedback data
C055
Over-torque(Forward-driving) level setting
C056
Over-torque(Reverse-regenerating) level setting
C057
Over-torque(Reverse-driving) level setting
C058
Over-torque(Forward-regenerating) level setting
C061
Electronic thermal warning level setting
C062
Alarm code input
C063
Zero speed detection level
C064
Heat sink overheat warning level
C071
Communication speed selection
C072
Node allocation
C073
Communication data length selection
C074
Communication parity selection
C075
Communication stop bit selection
C076
Selection of the operation after communication error
C077
Communication timeout limit before tripping
C078
Communication wait time
C079
Communication mode selection
C081
O input span calibration
C082
OI input span calibration
C083
O2 input span calibration
C085
Thermistor input tuning
C091
Debug mode enable
C101
UP/DOWN memory mode selection
C102
Reset mode selection
C103
Restart mode after reset
C105
FM gain adjustment
C106
AM gain adjustment
C107
AMI gain adjustment
C109
AM bias adjustment
C110
AMI bias adjustment
C111
Overload setting (2)
C121
O input zero calibration
C122
OI input zero calibration
C123
O2 input zero calibration
C130
Output 11 on-delay time
C131
Output 11 off-delay time
C132
Output 12 on-delay time
C133
Output 12 off-delay time
C134
Output 13 on-delay time
C135
Output 13 off-delay time
C136
Output 14 on-delay time
C137
Output 14 off-delay time
C138
Output 15 on-delay time
C139
Output 15 off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
C144
Logical output signal 1 operator selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
(*1)4000HF:0.00 to 99.99 , 100.0 to 120.0(Hz)
19
Monitored data or setting
SJ700:0.20 x "rated current" to 2.00 x "rated current" (A) / L700:0.20 x "rated current" to 1.50 x "rated current" (A)
(Current with digital current monitor output at 1,440 Hz)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
SJ700:0.0 to 2.00 x "rated current" (A) / L700:0.0 to 1.50 x "rated current" (A)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
SJ700:0.0 to 2.00 x "rated current" (A) / L700:0.0 to 1.50 x "rated current" (A)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.0 to 100.0 (%)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
SJ700: 0. to 200. (%) < 75kW and over:0. to 180.>
L700: 0. to 150. (%)
SJ700: 0. to 200. (%) < 75kW and over:0. to 180.>
L700: 0. to 150. (%)
SJ700: 0. to 200. (%) < 75kW and over:0. to 180.>
L700: 0. to 150. (%)
SJ700: 0. to 200. (%) < 75kW and over:0. to 180.>
L700: 0. to 150. (%)
0. to 100. (%)
00(Disabled) / 01(3-bit) / 02(4-bit)
0.00 to 99.99, 100.0 (Hz)
0. to 200.0 (℃)
02 (loopback test), 03 (2,400 bps), 04 (4,800 bps), 05 (9,600 bps), 06 (19,200 bps)
1. to 32.
7 (7 bits), 8 (8 bits)
00 (no parity), 01 (even parity), 02 (odd parity)
1 (1 bit), 2 (2 bits)
00 (tripping), 01 (tripping after decelerating and stopping the motor), 02 (ignoring errors),
03 (stopping the motor after free-running), 04 (decelerating and stopping the motor)
0.00 to 99.99 (s)
0. to 1000. (ms)
00(ASCII), 01(Modbus-RTU)
0. to 9999., 1000 to 6553(10000 to 65530)
0. to 9999., 1000 to 6553(10000~65530)
0. to 9999., 1000 to 6553(10000~65530)
0.0 to 999.9, 1000.
(Do not change this parameter, which is intended for factory adjustment.)
00 (not storing the frequency data), 01 (storing the frequency data)
00 (resetting the trip when RS is on), 01 (resetting the trip when RS is off),
02 (enabling resetting only upon tripping [resetting when RS is on])
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (restarting with active matching frequency)
50. to 200. (%)
50. to 200. (%)
50. to 200. (%)
0. to 100. (%)
0. to 100. (%)
SJ700:0.0 to 2.00 x "rated current" (A) <75kW and over:0.0 to 1.80 x "rated current">
L700:0.0 to 1.50 x "rated current" (A)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
Rated current of
inverterx 1..0
×
00
00
00
00
×
00
00
00
00
00
00
00
00
×
00
00
00
00
×
00
00
00
00
×
×
01
01
01
01
×
01
01
01
01
×
Rated current of inverterx 1..0
01
01
01
01
×
×
Rated current of inverterx 1..0
×
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
×
3.0
3.0
3.0
3.0
×
0.00
0.00
0.00
0.00
×
×
0.00
0.00
0.00
0.00
×
100.0
100.0
100.0
100.0
0.0
0.0
0.0
0.0
×
100.
100.
100.
100.
×
×
100.
100.
100.
100.
100.
100.
100.
100.
×
100.
100.
100.
100.
×
×
80.
80.
80.
80.
00
00
00
00
×
0.00
0.00
0.00
0.00
×
120.
120.
120.
120.
×
×
04
04
04
04
×
1.
1.
1.
1.
×
7
7
7
7
00
00
00
00
×
1
1
1
1
×
×
02
02
02
02
×
0.00
0.00
0.00
0.00
0.
0.
0.
0.
×
00
00
00
00
×
×
×
Factory set
×
×
00
00
00
00
×
00
00
00
00
×
00
00
00
00
00
00
00
00
×
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
0.
0.
0.
0.
20.
20.
20.
20.
Rated current of
×
inverterx 1..0
Factory set
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
×
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
0.0
0.0
0.0
0.0
×
×
00
00
00
00
×
00
00
00
00
00
00
00
00
×
00
00
00
00
×
00
00
00
00
×
Change
during operation
(allowed or not)
×

Advertisement

Table of Contents
loading

This manual is also suitable for:

L700 series

Table of Contents