Page 1
Powerful Inverter Hitachi Industrial Equipment Systems Co.,Ltd.
Page 2
OC-Trip Motor current 0.3Hz 1200 1500 1800 -100 -200 Speed (min Hitachi original 0Hz Domain Over-current suppress OFF sensorless vector control Keep 150% * torque at 0Hz speed signal Impact load Crane applications require high torque at starting *150%torque in case 1 frame big inverter...
Page 3
Functions and User Friendly. Programming [EzSQ: Easy Sequence] function Inverter control by Built-in Item Description Programming function Language type BASIC Like Supported Device Windows(DOS/V)OS:Windows98SE,Windows2000,WindowsXP) 1,024 steps or 6k byte Memory area (Smaller of these)Program is stored in internal of inverter. Simple sequence operation is realized by downloading to an Editor(Windows),Display(Windows) Programming...
Ease of Maintenance Easy Operation Easy-removable construction User selection of Parameter for maintenance functions Data comparison function Field replacement of cooling fan(s) and DC bus capacitor can be accomplished in a fraction of the time. Allows display of only parameters changed from default. Using Logic terminal move to SJ700 without wiring change.
Voltage less than 2 times of INV DC voltage E. Output frequency can be changed with UP/DOWN Function Lower than Hitachi motor Max. insulation voltage (1,250V) with analog signal as reference value. The frequency at (during regenerating operation increase the DC bus voltage may over power shutdown can be saved, too.
STANDARD SPECIFICATIONS 3-phase 200V class 3-phase 400V class Model Name Indication Model Configuration SJ700-055 H F E F 2 Applicable Applicable Motor Motor LFUF2 HFEF2 HFUF2 LFUF2 HFEF2 HFUF2 kW (HP) kW (HP) 0.4(1/2) 30(40) 0.75(1) 37(50) 1.5(2) 46(60) 2.2(3) 55(75) 3.7(5) 75(100)
OPERATION and PROGRAMMING SJ700 Series can be easily operated with the digital operator provided as standard. The digital operator can also be detached and can be used for remote-control. Multilingual (English, French, German, Italian , Spanish and Portuguese) operator with copy function (SRW-0EX) and digital operator with potentiometer are also available as options.
Page 10
TERMINALS MAIN CIRCUIT TERMINALS Terminal Description Terminal Arrangement Terminal Symbol Terminal Name 055 - 220LFUF2/HFEF2, 300 - 370LFUF2 R ( L1 ) , S ( L2 ) , T ( L3 ) Main power supply input terminals 300 - 550HFEF2, HFUF2 HFUF2 U ( T1 ) , V ( T2 ) , W ( T3 ) Inverter output terminals...
PROTECTIVE FUNCTIONS PROTECTIVE FUNCTIONS ● MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS × [◯ ] = Allowed = Not permitted Setting Change Default Setting Code Function Name during operation during operation Monitored data or setting -FE(CE) -FU(UL) (allowed or not) (allowed or not) ◯...
Page 12
× [◯ ] = Allowed = Not permitted Setting Change Default Setting Code Function Name during operation during operation Monitored data or setting -FE(CE) -FU(UL) (allowed or not) (allowed or not) × ◯ A013 O-L input active range start voltabe 0.
Page 13
× [◯ ] = Allowed = Not permitted Setting Setting Change Change Default Setting Default Setting Code Code Function Name Function Name during operation during operation during operation during operation Monitored data or setting Monitored data or setting -FE(CE) -FE(CE) -FU(UL) -FU(UL) (allowed or not) (allowed or not)
Page 18
PROTECTIVE FUNCTIONS Display Display on remote on digital operator/copy unit Name Cause(s) operator ERR1**** OC.Drive While at constant speed The inverter output was short-circuited, or the motor shaft is locked or has a OC.Decel During deceleration heavy load. These conditions cause excessive current for the inverter, so the Over-current protection During acceleration OC.Accel...
CONNECTING DIAGRAM Source type logic In case of 400V class, place a transformer for operating circuit to receive 200V. 200V - 240V+10%, -15% 50/60Hz±5% (T1)U SJ700 R(L1) (T2)V S(L2) (T3)W (+1)PD T(L3) DC link choke (*2)Remove connection with J51 (*2) when RoTo power is supplied T(J51) Dynamic braking unit (BRD)
Page 20
CONNECTING DIAGRAM Sink type logic In case of 400V class, place a transformer for operating circuit to receive 200V. 200V - 240V+10%, -15% 50/60Hz±5% (T1)U SJ700 R(L1) (T2)V S(L2) (T3)W (+1)PD T(L3) DC link choke (*2)Remove connection with J51 (*2) when RoTo power is supplied T(J51) Dynamic braking unit (BRD)
Page 21
SJ300 series into the SJ700 series. Copying the parameter settings (that you cannot copy the parameter settings from the SJ700 series to the SJ300 series because the SJ700 series has many new functions and additional parameters.) No display mode selection.
A max. 400Hz can be selected on the SJ700 Series. However, a two-pole motor can attain up to approx. 24,000 rpm, which is extremely dangerous.
Page 23
When an electromagnetic contactor is installed between the inverter and the motor, do not perform on-off switching during contactor running operation. When used with standard applicable output motors (standard three-phase squirrel-cage four-pole motors), the SJ700 Series Wiring does not need a thermal relay for motor protection due to the internal electronic protective circuit. A thermal relay, however,...
Need help?
Do you have a question about the SJ700 Series and is the answer not in the manual?
Questions and answers