Installation
60

Water connection

For compliance to The Water Supply (Water Fittings) Regulations
1999, please fit the double check valves included in the scope of
supply to the on-site water supply for every water inlet hose used.
The double check valves prevent water from the inlet hoses flowing
back into the on-site drinking water supply.
Non-return valves are included in the scope of supply.
The flow pressure must be a minimum of 100 kPa and must not ex-
ceed 1000 kPa. If the flow pressure is higher than 1000 kPa, a pres-
sure reducing valve must be used.
The machine must be connected to the water supply using the inlet
hoses included in the scope of supply.
 The connection points are subject to water supply pressure.
Turn on the stopcock slowly and check for leaks. Correct the posi-
tion of the seal and screw thread if appropriate.
The enclosed double non-return valves must be installed on the stop-
cock in every water inlet.