Craftsman 919.724572 Owner's Manual

Permanently lubricated tank mounted
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
Permanently Lubricated
Tank Mounted

AIR COMPRESSOR

Model No.
919.724572
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8
D27446 Rev. 0 9/16/02

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.724572

  • Page 1: Air Compressor

    Owner’s Manual Permanently Lubricated Tank Mounted AIR COMPRESSOR Model No. 919.724572 • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating.
  • Page 2: Table Of Contents

    If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase. This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. Max. Developed HP Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark.
  • Page 5 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
  • Page 7 WARNING: Risk of Burns WHAT CAN HAPPEN Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. WARNING: Risk from Moving Parts WHAT CAN HAPPEN Moving parts such as the pulley, flywheel, and belt can cause serious injury if they com into contact with you or your clothing.
  • Page 8 Risk Unsafe Operation WARNING: WHAT CAN HAPPEN Unsafe operation of your air compressor could lead to serious injury or death to you or others. D27446 HAZARD HOW TO PREVENT IT Review and understand all instructions and warnings in this manual.
  • Page 9: Glossary

    • Quick Connector Sets (various sizes) Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because GLOSSARY When the tank pressure drops to a certain low level the motor will restart automatically.
  • Page 10: Installation

    HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
  • Page 11 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Attach extra air hoses at the air outlet instead of using extension cords. If an extension cord must be used, be sure it is: •...
  • Page 12: Operation

    "cut-out” pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out” pressure setting, the safety valve will protect against high pressure by "popping out” at its factory set pressure (slightly higher than the pressure switch "cut-out”...
  • Page 13: How To Use Your Unit

    This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. Make sure the On/Auto/Off lever is in the "OFF"...
  • Page 14 Before Each Start-Up: Place On/Auto/Off lever to "OFF" and close air regulator. Pull regulator knob out, turn counterclockwise until it stops. Push knob in to lock in place. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.
  • Page 15: Maintenance

    After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.
  • Page 16: Service And Adjustments

    ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY A TRAINED SERVICE TECHNICIAN. Before servicing: Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure Allow the air compressor to cool. To Replace or Clean Check Valve Release all air pressure from air tank.
  • Page 17 To Replace Regulator Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Unplug unit. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator. Outlet Pressure Gauge Quick Regulator Connect Remove the regulator.
  • Page 18: Storage

    Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped) Store the air compressor in a clean and dry location. 18- ENG Water will condense in the air...
  • Page 19: Troubleshooting

    Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM...
  • Page 20 PROBLEM Pressure reading It is normal for "some" on the regulated pressure drop to occur. pressure gauge drops when an accessory is used. Possible defect in safety Knocking Noise. valve. Defective check valve. Prolonged excessive use of Compressor is air. not supplying enough air to Compressor is not large...
  • Page 21 PROBLEM Regulator will Damaged regulator. not shut off air outlet. Motor will not Motor overload protection run. switch has tripped. Tank pressure exceeds pressure switch "cut-in" pressure. Extension cord is wrong length or gauge. Check valve stuck open. Loose electrical connections. Check wiring connection Possible defective motor or starting capacitor.
  • Page 22 à compter de la date d’achat, sur un compresseur qui est utilisé à des fins commerciales ou comme appareil de location Cette garantie sur le compresseur d'air de Craftsman vous donne des droits particuliers. Il se peut que vous ayez d’autres droits qui varient d’une province à l’autre.
  • Page 23: Tableau Des Spécifications

    TABLEAU DES SPÉCIFICATIONS Modèle no : CV maximum développés Alésage Course du cylindre Tension – phase unique Exigence minimale du circuit de dérivation Genre de fusible Capacité du réservoir d’air Pression d’enclenchement approx. Pression de coupe-circuit approx. Pi3/min standard (SCFM) à 40 psi (lb/po. ca.) Pi3/min standard (SCFM) à...
  • Page 24 RISQUE DE CHOC ÉLECTRIQUE RISQUE VOTRE COMPRESSEUR D’AIR EST ALIMENTÉ PAR ÉLECTRICITÉ. COMME AVEC TOUS LES APPAREILS ÉLECTRIQUES, SI L’APPAREIL N’EST PAS UTILISÉ DE FAÇON APPROPRIÉE, IL PEUT CAUSER DES CHOCS ÉLECTRIQUES. TOUTE RÉPARATION EFFECTUÉE PAR UNE PERSONNE NON QUALIFIÉE PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR ÉLECTROCUTION.
  • Page 25 RISQUE DE BRÛLURES RISQUE LE FAIT DE TOUCHER AUX SURFACES DE MÉTAL EXPOSÉES TELLES QUE LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE GRAVES BRÛLURES À LA PEAU. RISQUE RELIÉ AUX PIÈCES MOBILES RISQUE LES PIÈCES MOBILES TELLES QUE LA POULIE, LE VOLANT-MOTEUR ET LA COURROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES ENTRENT EN...
  • Page 26 RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT DU COMPRESSEUR (incendie, inhalation, dommages aux surfaces du véhicule) RISQUE DES FUITES OU DES DÉVERSEMENTS D’HUILE PEUVENT SE PRODUIRE ET ENTRAÎNER DES RISQUES D’INCENDIE, OU DES PROBLÈMES AUX VOIES RESPIRATOIRES, DES BLESSURES GRAVES OU LA MORT. DES FUITES D’HUILE ENDOMMAGENT LES TAPIS, LA PEINTURE ET TOUTE AUTRE SURFACE DES VÉHICULES OU DES REMORQUES.
  • Page 27: Lexique

    Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM : pieds cubes par minute (pi SCFM : pieds cubes par minute (pi standard. Une unité de mesure de débit d'air. PSIG: jauge indiquant le nombre de livres par pouce carré (lb/po ).
  • Page 28 CÓMO PREPARAR LA UNIDAD Ubicación del compresor de aire Ubique al compresor de aire en una zona limpia, seca y bien ventilada. La bomba del compresor de aire y su carcasa han sido diseñadas para permitir un enfriamiento adecuado. Las aberturas de ventilación del compresor resultan - entonces - necesarias para el mantenimiento de una adecuada...
  • Page 29 Rallonges Utilisez un boyau d'air supplémentaire au lieu d'une rallonge pour éviter une chute de tension, une perte de puissance et la surchauffe du moteur. Si une rallonge doit être utilisée, s'assurer : • d'utiliser une rallonge à trois fils, munie d'une fiche à...
  • Page 30: Utilisation

    Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures. Interrupteur "On/Auto/Off"...
  • Page 31 Pompe du compresseur d'air (non illustrée) : La pompe comprime l'air pour le forcer dans le réservoir d'air. L'air n'est pas disponible pour travailler avant que le compresseur n'ait élevé la pression du réservoir d'air au niveau requis à la sortie d'air.
  • Page 32 Avant chaque mise en marche : Placez le levier "On/Auto/Off" à la position "OFF". Tirez le bouton du régulateur et tournez-le dans le sens contraire des aiguilles d'une montre jusqu'à ce qu'il s'arrête. Poussez le bouton pour le verrouiller. Raccordez le boyau et les accessoires.
  • Page 33: Entretien

    Responsabilités du client Vérifier la soupape de sûreté Vidanger le réservoir L'appareil fonctionne automatiquement en cycles lorsqu'il est sous tension. En effectuant l'entretien, vous pouvez être exposé aux sources de tension, à l'air comprimé ou aux pièces mobiles et subir ainsi des blessures corporelles.
  • Page 34 ENTRETIEN ET RÉGLAGES d'air fonctionne automatiquement lorsqu'il est sous tension. En effectuant l'entretien, vous pourriez être exposé aux sources de tension, à de l'air comprimé ou aux pièces en mouvement et subir ainsi des blessures corporelles. Avant de procéder à tout entretien ou réparation, débranchez le compresseur et purgez tout l'air pressurisé.
  • Page 35 Remplacement du régulateur Déchargez tout l'air pressurisé du réservoir d'air. Voir la partie intitulée "Vidange du réservoir" de la section sur l'entretien. Débranchez le compresseur d'air. À l'aide d'une clé réglable, retirez du régulateur le manomètre de sortie et le raccord à connexion rapide. Retirez le régulateur.
  • Page 36: Rangement

    Avant de ranger le compresseur d'air, effectuez les étapes suivantes : Revoyez la section intitulée "Entretien" des pages précédentes et exécutez l'entretien requis. Placez le levier "On/Auto/Off" à la position "OFF". Tournez le régulateur dans le sens contraire des aiguilles d'une montre et réglez la pression de sortie à...
  • Page 37 pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corporelles. Débranchez le compresseur et purgez l'air pressurisé du réservoir avant d'entamer toute réparation. PROBLÈME Le manostat n’arrête pas le moteur Pression excessive - lorsque le compresseur d'air atteint la soupape de sûreté...
  • Page 38 PROBLÈME Le relevé de pression Une légère chute de pression est sur le manomètre du considérée normale. régulateur tombe lorsqu'un accessoire est utilisé. Utilisation prolongée et excessive de Le compresseur d'air ne fournit pas l'air. suffisamment d'air Le compresseur n'est pas assez gros pour faire fonctionner pour la quantité...
  • Page 39 PROBLÈME Fusible sauté ou coupe-circuit Le moteur ne tourne déclenché. pas. Rallonge de longueur ou de calibre inapproprié. Connexions électriques desserrées. Moteur défectueux. CAUSE Vérifiez s'il y a un fusible sauté dans la boîte à fusibles et remplacez-le au besoin. Rétablissez le coupe-circuit. Ne pas utiliser un fusible ou un coupe- circuit à...
  • Page 40 1-800-4-MY-HOME in your own home … Sears Parts and Service Sears Parts & Service, www.sears.ca 1-800-361-6665 1-800-LE-FOYER www.sears.ca...

Table of Contents