6.3.2

Rechargeable battery

The battery is protected against deep discharge,
overcharging, overheating and short circuits by
Electronic Cell Protection (ECP). In the event of a
hazard, a protective circuit switches the battery off
automatically. If a fault is detected in the battery,
the LEDs flash on the battery level indicator.
Description
Code:
If the battery is outside its
charging temperature range,
three LEDs will flash on the
battery level indicator.
Code:
If a fault is detected in the
battery, two LEDs flash on the
battery level indicator.
Code:
No LEDs will flash if the charger
is defective and will not charge.
One or more LEDs will light up
permanently, depending on the
battery level.
Code:
No LEDs will light up if there is
no power.
Table 43: List of battery error messages
MY22K01 - 32_1.0_26.08.2021
All manuals and user guides at all-guides.com
Method of resolution
1
Disconnect charger from
battery.
2
Leave battery to cool
down.
3
Contact your specialist
dealer if the problem
persists.
 Contact your specialist
dealer.
 Contact your specialist
dealer.
1
Check all plug
connections.
2
Check contacts on the
battery for dirt. Clean the
contacts carefully if
needed.
3
Contact your specialist
dealer if the problem
persists.
Operation