Page 4
Replacing a system fan 10.12 Replacing the power supply 10.12.1 Replacing the power supply 10.12.2 Replacing the power distributor 10.13 Monitoring the system 10.14 Installing Video Recording Manager locally 10.15 Service and repair 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
The Low Voltage power supply unit must comply with EN/UL 60950. The power supply must be a SELV-LPS unit or a SELV - Class 2 unit (Safety Extra Low Voltage - Limited Power Source). Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings before operating the device. – Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Page 7
– For protection of the device, the branch circuit protection must be secured with a maximum fuse rating of 16 A. This must be in accordance with NEC800 (CEC Section 60). Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
SELV circuits. – If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems. –...
Notices Notice! This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
DIVAR IP 6000 (2U) Notice! Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of losing information, we recommend multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Page 11
Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the chassis. Installation and maintenance should be performed by experienced and qualified technicians only. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
. Always use the air shroud included with your chassis. 3.2.5 Mounting rails The unit can be placed in a rack for secure storage and use. To set up your rack, follow the step-by-step instructions included in this manual. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
You should also check to make sure that the chassis covers are installed. Finally, verify that the heat sinks are installed properly. This LED will remain flashing or on as long as the fan failure/overheat condition exists. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
LED to blink on and off when that particular drive is being accessed. – Red: The red LED indicates a SATA drive failure. If one of the SATA drives fail, you should be notified by your system management software. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
If the chassis itself shows damage, file a damage claim with the carrier who delivered it and notify the respective Bosch RMA desk. Due to the weight of the system: After opening the top of the shipping box, one person should stand at either end and lift the disk array out together.
This rail will fit a rack between 26" and 33.5" deep. 4.3.1 Separating the sections of the rack rails The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of two sections: 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Caution! Do not pick up the chassis with the front handles. They are designed to pull the system from a rack only. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Secondly, these tabs also lock the system in place when fully extended from the rack. This prevents the system from coming completely out of the rack when you pull it out for servicing. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Optional screws may be used to secure the front of the chassis to the rack. 4.3.5 Installing the chassis in a Telco rack Notice! Do not use a two post "Telco" type rack. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. We recommended using an uninterruptible power supply (UPS). Press the power button on the control panel to turn on the system. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Open the Microsoft Utility Server Manager and follow the instructions on the screen to configure the network interface cards (NICs). IP Helper tool The IP Helper tool is available for download as follows: Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
The system comes with iSCSI Target Service enabled. Notice! On empty systems you must set up the iSCSI target and the iSCSI LUNs of the drives manually after initial RAID configuration. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
18. Finish the wizard and exit the Server Manager program. Notice! Before you can store video recordings on the drive, you must perform a basic setup using the video software configuration tool, for example, Configuration Manager or Bosch VMS Configuration Client. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Select all hard drives that are part of the RAID group. Start the virtual drive initialization. Exit the MegaRAID Configuration Utility program. Perform a complete system recovery (Initial Factory Setup). See also – Recovering the unit, page 27 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
After the restart of the unit, the factory default settings are installed and the Windows logon screen is displayed. The factory default settings are: – IP address: DHCP (Fallback: 192.168.0.200) – Subnet mask: 255.255.255.0 – User: BVRAdmin – Password: WSS4Bosch Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Software for configuration of hardware and software is available on the online product catalogue. Documentation and software for Bosch Security Systems products can be found in the online product catalogue as follows: Open any browser > enter www.boschsecurity.com > select your region and your country >...
This chapter provides an overview on used Open Source Licenses in DIVAR IP 6000. The license packages are either used completely or only some parts within a package are used. MIT - iniparser Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Although not frequently, you may need replacement parts for your system. To ensure the highest level of professional service and technical support, you must register the systems according to the instructions available as part of the shipment as well as online from the Bosch product catalog. 10.2 Removing power from the system Before performing some setup or maintenance tasks, use the following procedure to ensure that power has been removed from the system.
Hard drive carrier handle To remove a hard drive from the chassis: Press the release button to the right of the hard drive carrier. This extends the hard drive carrier handle. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
Slide a new hard drive into the hard drive carrier with the printed circuit board side facing down. Align the mounting holes in both, the hard drive carrier and the hard drive. Secure the hard drive to the hard drive carrier using six screws. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Notice! We recommend using the respective Bosch hard disk drives. The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates. HDD – not delivered from Bosch – are not supported. Information on supported HDDs can be found in the datasheet in the Bosch Online Product Catalog.
Align the mounting holes in both, the hard drive carrier and the hard drive. Note: There are mounting holes in the hard drive carrier marked "SAS" or “SATA” to aid in correct installation. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
Notice! We recommend using the respective Bosch hard disk drives. The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates. HDD – not delivered from Bosch – are not supported. Information on supported HDDs can be found in the datasheet in the Bosch Online Product Catalog.
Make sure that your air shroud matches your chassis model. Turn off the system and remove the cover. Place the air shroud in the chassis. The air shroud fits behind the two fans closest to the power supply. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.1 | DOC...
This unit might have more than one power supply connection. To de-energize the unit, remove all connections. LED status: – Amber lighted LED: The power supply is off. – Green lighted LED: The power supply is operating. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
The power supply can be replaced without turning off the system if a redundant power supply is available. Replacement units can be ordered directly from Bosch RMA desk. To replace the power supply: You can leave the unit running and remove only one power supply if your chassis includes a redundant power supply.
Turn on the unit and log on as user BVRAdmin. The default screen is displayed. Double-click the Download Video Recording Manager icon on the screen. Download and install the Video Recording Manager installation package. Note: After installation Video Recording Manager is pre-licensed with 64 channels. 2016.08 | V2.1 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
The storage equipment is shipped with an original manufacturer Service and Support agreement. Bosch RMA Desk is the Single Point of Contact in case of failure but the Service and Support obligations are fulfilled by the manufacturer or a partner.