④ Earth Rod
WARNING
• The Unit must be earthed.
• Earth Rod fixing procedure. Select suitable place to bury the optional Earth Rod (DQ-6H) for at least 70 cm below ground surface.
• Ensure that the ground resistance is less than 100 Ω. If it is not, drive the Earth Rod deeper into ground surface or use 2 or 3 Earth Rods.
Burying tool
Earth Rod
Ground
Surface
5. Piping installation procedure
① Place Rubber Packing between Filter Body Assembly and Flexible Pipe.
Do not use Piping Tape. Tighten it by Spanner firmly.
② Place Rubber Packing between Filter Body Assembly and Main Body.
Do not use Piping Tape. Tighten it by hand firmly.
③ Place Rubber Packing between Shower Hose and Main Body.
Do not use Piping Tape. Tighten it by hand firmly.
④ Place Rubber Packing between Shower Hose and Shower Head.
Do not use Piping Tape. Tighten it by hand firmly.
⑤ The Filter Body Assembly should be placed in the front direction of the Unit.
WARNING
Do not share the inlet or outlet pipe of Home Shower Unit
with other outlets.
The pressure may drop due to water being drawn off at other point.
The shower water temperature may become very hot.
CAUTION
Avoid using dirty water as it may affect heater performance
and other components.
NOTE:
* Make sure no water leaks from pipe connection.
* When glue is used for external piping connection, must wait for the glue
to dry before proceed to test run with water.
⑥ Adjust Holder Adjustment. (Behind Filter Body Assembly).
Set the Adjust Holder behind the Filter Body Assembly
by turning it anticlockwise or clockwise. Make sure the
Adjust Holder is touching to the wall or tiles.
If the Adjust Holder needs to be cut due to different wall
height make sure the Adjust Holder is touching to the wall
or tiles to prevent possibility of water leakage at the Filter
Body Assembly.
The Unit must be earthed.
Improper grounding could cause electric shock.
(Bevel Style)
70 cm at least
70 cm at least
- 10 -
(Parallel Style)
Connection
70 cm at least
1 m
L
N
Shower Head
Main Body
Rubber
Packing
Shower
Filter Body
Hose
Assembly
Parts not
included
Use flexible
pipe minimum
length 150 mm
Water Outlet
wall/tiles
Adjust Holder
About 5 mm
Cut
tiles
Connection
About 2 m
About 2 m
Thread End
L
N
Filter Body
Assembly
Water Inlet
Touching to
the wall/tiles
Touching to
the wall/tiles
tiles