Replacing A Storage Controller; Identify The Failed Storage Controller - Dell SCv2080 Owner's Manual

Storage center
Hide thumbs Also See for SCv2080:
Table of Contents

Advertisement

Figure 23. Replace the Storage Controller Battery
1.
Battery
3.
Storage controller
2.
Align the replacement battery with the slot on the storage controller.
3.
Slide the battery into the storage controller until the release tab clicks into place.
Next steps
1.
Use SupportAssist to send diagnostic data to Dell Technical Support Services.

Replacing a Storage Controller

The SCv2080 storage system supports redundant hot-swappable storage controllers.
Storage controllers provide the following data path and storage management functions for the storage
system:
Monitoring and controlling some storage system environment elements such as temperature, fan,
power supplies, and storage system LEDs
Controlling access to hard drives
Communicating storage attributes and states to the storage system
NOTE: Do not return the storage controller battery with the failed storage controller. A new battery
is not included with a replacement storage controller.

Identify the Failed Storage Controller

To determine which storage controller failed, use the Dell Storage Client .
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
storage controller.
Replacing SCv2080 Components
Get other manuals https://www.bkmanuals.com
2.
Release tab
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

E11j

Table of Contents