4 - INSTALLATION

TECHNICAL INFORMATION FOR THE
INSTALLER
In order to install the cooker top into the
kitchen fixture, a hole with the dimensions
shown in fig. 4.2 has to be made, bearing in
mind the following:
If the cooktop is installed directly above
an oven or if its base is accessible
through a cupboard or drawer space
after installation, a thermal protection
barrier must be installed below the base
of the cooktop as indicated in fig. 4.3.

The thermal protection barrier must be:
removable with the use of a tool for
installation and service;
heat-resistant;
made from low thermal conductivity
material.
A 30 mm ventilation gap must be provided
between the bottom of the appliance and
any
cabinetry,
draw unit, thermal
protection barrier
or appliance.
If the cooktop is
installed
an oven, the two
appliances
be connected to
the
gas
and/or
electrical
supply
with independent
connections.
The cooker top
must be kept no less than 200 mm away
from any side wall (fig. 4.2).
The hob must be installed at least 60 mm
from the wall (fig. 4.2).
There must be a distance of at least
650 mm between the hob and any wall
cupboard or extractor hood positioned
immediately above (see fig. 4.1).
14
above
shall
Fig. 4.1
Clearance
Door
Space for
connections
Fig. 4.2
Fig. 4.3
Thermal
protection
barrier