Owon ODP3033 User Manual
Owon ODP3033 User Manual

Owon ODP3033 User Manual

Triple output linear programmable dc power supply

Advertisement

Quick Links

ODP Series Triple Output
Linear Programmable DC Power Supply
User Manual
■ ODP3033
■ ODP3063
■ ODP6033
For product support, visit:www.owon.com.hk/download

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ODP3033 and is the answer not in the manual?

Questions and answers

Summary of Contents for Owon ODP3033

  • Page 1 ODP Series Triple Output Linear Programmable DC Power Supply User Manual ■ ODP3033 ■ ODP3063 ■ ODP6033 For product support, visit:www.owon.com.hk/download...
  • Page 2 LILLIPUT Company. Fujian LILLIPUT Optoelectronics Technology Co., Ltd. No. 19, Heming Road Lantian Industrial Zone, Zhangzhou 363005 P.R. China Tel: +86-596-2130430 Fax: +86-596-2109272 Web: E-mail: www.owon.com info@owon.com.cn...
  • Page 3 product.
  • Page 4: Table Of Contents

    Table of Contents 1. General Safety Requirements..................1 2. Safety Terms and Symbols ..................2 3. Quick Start ........................ 3 3.1 Front/Rear Panel and User Interface ................3 3.1.1 Front Panel ..........................3 3.1.2 Rear Panel............................ 5 3.1.3 User Interface ..........................5 Mode Icons ..................................
  • Page 5 4.8 System Info ........................18 4.8.1 View System Information ......................18 4.8.2 Set as Default ..........................18 4.8.3 Update ............................20 4.9 Port Settings ........................ 21 4.9.1 Serial port ..........................21 4.9.2 LAN Set ............................21 4.9.3 LCD Test ............................. 21 4.9.4 Key Test .............................
  • Page 6: General Safety Requirements

    1.General Safety Requirements 1. General Safety Requirements Before use, please read the following safety precautions to avoid any possible bodily injury and to prevent this product or any other connected products from damage. To avoid any contingent danger, ensure this product is only used within the ranges specified.
  • Page 7: Safety Terms And Symbols

    2.Safety Terms and Symbols 2. Safety Terms and Symbols Safety Terms Terms in this manual (The following terms may appear in this manual): Warning: Warning indicates conditions or practices that could result in injury or loss of life. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property.
  • Page 8: Quick Start

    3.Quick Start 3. Quick Start 3.1 Front/Rear Panel and User Interface 3.1.1 Front Panel ② ① ③ ④ ⑤ ⑥ ⑯ ⑦ ⑮ ⑧ ⑭ ⑪ ⑨ ⑬ ⑫ ⑩ Figure 3-1 Front panel overview ① LCD User interface display ②...
  • Page 9 3.Quick Start ⑧ CH2 control area Blue Volt/CV key: Set the output voltage of CH2 Blue Curr/CC key: Set the output current of CH2 Blue ON/OFF key: Enable/disable the output of CH2 ⑨ CH2 output Channel 2 output connectors terminals ⑩...
  • Page 10: Rear Panel

    3.Quick Start 3.1.2 Rear Panel ③ ① ② ④ ⑥ ⑤ Figure 3-2 Rear panel overview ① Local Area The power supply can be connected to the network for Network (LAN) remote control via this connector. Connector ② USB Device Connect as a "slave device"...
  • Page 11: Mode Icons

    3.Quick Start Constant Voltage output Channel 1 Channel 2 Constant Current outpu Mode icon Actual power output Actual voltage output Status icons Actual current output Set values of voltage Set values of current Set values of O.V.P/O.C.P Figure 3-3 User interface in All channel mode ⚫...
  • Page 12: Status Icons

    3. Check the Complete Instrument If there is any physical damage, operational fault, or performance issue please contact your distributor or OWON’s local office. If there is any transportation damage to the instrument please ensure you keep the original packaging. Ideally you should always keep the original packaging if the instrument must be returned for repair.
  • Page 13: Output Inspection

    3.Quick Start (2) Push the power button on the front panel, the keys will light and the screen will show the boot screen. 3.4 Output Inspection Output inspection is to ensure that the instrument can achieve its rated outputs and properly respond to operation from the front panel.
  • Page 14: Front Panel Operation

    4.Front Panel Operation 4. Front Panel Operation 4.1 Turn On/Off the Channel Output Press the orange ON/OFF key to turn on/off the Channel 1 output. Press the blue ON/OFF key to turn on/off the Channel 2 output. Press the ON/OFF CH3 key to turn on/off the Channel 3 output. 4.2 Set the Output Voltage/Current 4.2.1 Set the Output Voltage ⚫...
  • Page 15: Over Voltage/Current Protection

    4.Front Panel Operation Press the blue Curr/CC key to enter edit mode. You can set the value in the same way as CH1 above. ⚫ Set the output current of CH3 Press the Curr CH3 key to enter edit mode. You can set the value in the same way as CH1 above.
  • Page 16: Programmable Output

    4.Front Panel Operation Press the orange Curr/CC key, the first digit of the CH1 set current is flashing. Press the ▼ key, the first digit of the CH1 O.C.P is flashing, indicating the value is editable. There are two methods to change the value. Modify: Turn the knob to change the value.
  • Page 17: Data Process

    4.Front Panel Operation (3) Press the ▼ key to select Stop Point submenu. Use the numeric keys to input (1 to 100), press the key to confirm. (4) Press the ▼ key to select Start submenu. Press the < / > key to select the channel (CH1, CH2 or ALL), press the key to enter the data processing interface and output the selected channel.
  • Page 18: Turn On/Off Programmable Output

    4.Front Panel Operation displayed in the chart in the data processing interface. (3) Press ← to back to sub menu selection. 4.4.4 Turn On/Off Programmable Output In the data processing interface: ⚫ Independent Mode Press orange ON/OFF key to turn on/off the programmable output of Channel 1. Press blue ON/OFF key to turn on/off the programmable output of Channel 2.
  • Page 19: Auto Record

    4.Front Panel Operation sub menu selection. (4) Press the ▼ key to select Recall submenu. Press the key, a red box will show in the table, indicating the selected item. Press the ▲ / ▼ key to select. Press the < / >...
  • Page 20 4.Front Panel Operation the < / > key to select the channel (CH1, CH2 or CH3), press the key to read the recording file of the selected channel. After reading successfully, if the display mode is set as Table, a red box will show in the table, indicating you can press the <...
  • Page 21: Output Mode

    4.Front Panel Operation 4.6 Output mode Output mode can simplify the parameter inputting of CH1 and CH2. Output mode setting is only for CH1 and CH2, without affecting CH3. There are four output modes: ⚫ Independent Output The parameter of each channel can be set independently. ⚫...
  • Page 22 4.Front Panel Operation The voltage rating is the sum of CH1 and CH2 voltage rating; the current rating is same as the single channel. Press the orange ON/OFF key to turn on/off the combined channel. CH1 and CH2 Series in series The connection method of the series connection of CH1 and CH2 is as shown in the figure below.
  • Page 23: Utility Settings

    4.Front Panel Operation (2) Press the ▲ / ▼ key to select the output mode. Press the key to check and enter the selected mode. 4.7 Utility Settings 4.7.1 Language Press the Utility key, turn the knob to select [Utility]. The Language sub menu is selected. Press the <...
  • Page 24 4.Front Panel Operation 3.30V 0.50A Parallel 12.000V 4.000A Series 24.000V 2.000A Output VOLT CURR Limit MAXOUT+1V MAXOUT+0.1A settings Parallel MAXOUT+1V 2*(MAXOUT+0.1A) Series 2*(MAXOUT+1V) MAXOUT+0.1A Output mode Independent mode Brightness Beeper Baud 115200 Data Bits Serial Utility Odd-Even None Stop Bits Port 192.168.001.099 Subnet Mask...
  • Page 25: Update

    (1) Press the Utility key, turn the knob to select [Info]. The Info sub menu is selected. You can view the model and firmware version. (2) From a PC, visit www.owon.com and check if the website offers a newer firmware version. Download the firmware file. The file name must be ODPFW.upp. Copy the firmware file onto the root directory of your USB memory device.
  • Page 26: Port Settings

    4.Front Panel Operation 4.9 Port Settings 4.9.1 Serial port Press the Utility key, turn the knob to select [Port Set]. The Serial sub menu is selected. key to enter sub menu. The Baud is selected. Press the < / > (1) Press the key to select the desired baud rate from 1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200.
  • Page 27: Troubleshooting

    (the cover can be pried open with a straight screwdriver). ⚫ Restart the instrument after the steps above. ⚫ If the problem still exists, please contact OWON for our service. 2. The output is abnormal: ⚫ Check if the output voltage is set to 0V. If so, set it to other value.
  • Page 28: Technical Specifications

    The specifications below are based on the instrument having run for at least 30 minutes continuously under the specified operating temperature. Specifications Voltage 0-30V 0-6V Over Voltage 6.6V Protection ODP3033 Current 0-3A 0-3A Over Current 3.1A 3.1A Protection Power Voltage...
  • Page 29 480 (Horizontal) × 320 (Vertical) Pixels Display Colors 65536 colors, TFT screen Power Supply 110 VAC ± 10% or 220 VAC ± 10%; AC input 50/60Hz 110 V 250 V,F5A ODP3033 220 V 250 V,F3A Fuse ODP3063 110 V 250 V,F10A ODP6033 220 V 250 V,F5A...
  • Page 30: Appendix

    7.Appendix 7. Appendix 7.1 Appendix A: Packaging (The accessories subject to final delivery.) Standard Accessories: Power Cord CD Rom User Manual USB Cable Fuse Options: Banana plug to crocodile clip test leads 7.2 Appendix B: General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display could be exposed to direct sunlight for long periods of time.
  • Page 31 7.Appendix Warning: Before re applying power, ensure that the instrument is completely dry, avoiding any electric shock or electrical short circuit resulting from moisture.