Introduction This technical manual describes the system board D2509, which can be ® equipped with one or two Intel XEON™ processors. Further information about drivers is provided in the readme files on the hard disk, on the supplied “ServerStart“ or “Update“ CDs.
Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. ● The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2509 (TX200 S4)
Page 8
Incorrect replacement of lithium battery may lead to a risk of ● explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2509 (TX200 S4)
Page 9
Place all components on a static-safe base. ● You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2509 (TX200 S4)
Never use sharp objects (screwdrivers) for leverage. ● CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2509 (TX200 S4)
Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2509 (TX200 S4)
Page 12
You will find further information on this at www.fujitsu- siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
Page 15
SSI EEB Baseboard 304,8 x 330,2 mm (12 x 13 inch) CSS (Customer Self Service) This system board supports the CSS functionality. You will find a description of CSS functionality in the operating manual of your server. Technical Manual D2509 (TX200 S4)
FBD533/PC2-4200F or FDB667/PC2-5300 fully buffered DIMM modules and must be populated in pairs. It is only allowed you use memory modules released by Fujitsu Siemens Computers. – Each pair must consist of identical memory modules (2 way interleaved mode).
Page 18
An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. The interrupts are defined by the system design. Technical Manual D2509 (TX200 S4)
Page 19
PCI_INTA, PCI_INTB, PCI_INTC, PCI_INTD Slot 1 PCIe x8 PCI_INTA, PCI_INTB, PCI_INTC, PCI_INTD Assignment of the PCI interrupts If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. Technical Manual D2509 (TX200 S4)
C temperature sensor. Fan monitoring The CPU, power supply unit and system fans are monitored. Fans that are no longer available, blocked or sticky fans are detected. Technical Manual D2509 (TX200 S4)
Page 21
LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView. PRIMERGY Diagnostic LEDs Optical signaling through the LEDs on the system board identifies defective modules and components as well as gaining information on the PDA. Technical Manual D2509 (TX200 S4)
LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the indicate CSS button. Technical Manual D2509 (TX200 S4)
Page 23
F - system fan running fans orange fan failure G - CPU fans fan running orange fan failure H - PCI card PCI card okay orange PCI card failure Technical Manual D2509 (TX200 S4)
The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key). 3.7.1 External ports Figure 6: External ports of the system board D2509 1 = CSS LED (yellow) 6 = USB port Global Error LED (orange)
Page 26
Figure 7: LAN connector single-channel Gigabit LAN controller 1 LAN transfer rate green + transfer rate 10 Mbit/s yellow green transfer rate 100 Mbit/s yellow transfer rate 1000 Mbit/s 2 LAN link/activity green LAN connection no LAN connection flashing LAN transfer Technical Manual D2509 (TX200 S4)
The system boots from the “Flash BIOS floppy disk“ from drive A and reprograms the system BIOS on the board. The System BIOS is started with the system BIOS from the system board (default setting). Technical Manual D2509 (TX200 S4)
Page 28
To write and delete floppy disks, the write-protection in BIOS Setup must be disabled (in menu Security, the field Diskette Write must be set to Enabled). The floppy disk drive is write-protected. Floppy disks can be read, written and deleted (default setting). Technical Manual D2509 (TX200 S4)
Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2509 (TX200 S4)
Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module Technical Manual D2509 (TX200 S4)
Page 33
Light Emitting Diode Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) Technical Manual D2509 (TX200 S4)
Page 34
Real Time Clock Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide System Management Bus Server Management Mode Technical Manual D2509 (TX200 S4)
Page 35
Abbreviations Symmetrically Multi Processing UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2509 (TX200 S4)
Page 37
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.