InstallatIon Manual
Risk of fire or electrical shock exists if an incor-
rect size range cord kit is used, or the installation instructions are
not followed precisely and/or a strain relief clamp is not used.
Do not loosen the nuts which secure the factory-in-
stalled range wiring to the terminal block while connecting range.
Electrical failure or loss of electrical connection may occur.
electRIcal shock hazaRd
• DISCONNECT POWER TO THE CIRCUIT BREAKER
OR FUSE BOX BEFORE MAKING THE ELECTRICAL
CONNECTION.
• Electrical ground is required on this range.
• Do not connect to the electrical supply until range is permanently
grounded.
• This range must be connected to a grounded, metallic,
permanent electrical system or the grounding connector of the
power cord should be connected to the grounding terminal or
wire lead on the range.
• Failure to heed these warnings could result in a fire, personal
injury or electrical shock.

Model and seRIal nuMbeR locatIon

The rating plate, including model and serial number, is located on
the faceplate behind the Microwave Drawer front.
08/0 Volt connectIon InstRuctIons
The range can be set for 208V or 240V. The voltage setting for your
range is pre-set at 240V from the factory. Follow these steps to
change the voltage setting.
 Locate the voltage switch on the lower back side of the range.
 Remove the screw and rotate the switch plate 180˚ as indicated
in the Figure 3.
 Reinsert the switch plate and replace screw as indicated in Figure
4. The voltage setting is indicated by the visible marking.
180˚
screw
Figure 
Rating plate
screw
Figure 
 & -wIRe electRIcal wall Receptacle types &
RecoMMended MountIng oRIentatIon on wall
Figure 5A illustrates 4-wire receptacle required for new and
remodeled installations.
Figure 5B illustrates 3-wire receptacle that is allowed for existing
installations.
4-wire wall receptacle (14-50R)
Figure 5a
access to teRMInal block
Loosen screw on rear access cover and pull down as illustrated in
Figure 6 to access terminal block wiring connection.
screw
Figure 6
PoWER CoRD ConnECtIons
-wIRe connectIon InstRuctIons
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting to a 4-wire electrical system for a
new branch-circuit or mobile home use a 4-wire connection.
 Follow the power supply cord kit manufacturer's Installation
Instructions and install the strain relief clamp on the cord. See
Figure 7.
 Connect the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 8.
DO NOT LOOSEN the factory installed nut
IMpoRtant
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
 You must disconnect the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw. See Figure 8.
 Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the

3-wire wall receptacle (10-50R)
Figure 5b
strain relief clamp
Figure 7