Advertisement

Owner's Operation and Instruction Manual
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE
YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
CAUTION!
Please read this entire manual before you
install or use your new room heater. Failure
to follow instructions may result in property
damage, bodily injury, or even death.
Improper Installation Could Void
Your Warranty!
SAFETY NOTICE:
If this heater is not properly installed, a house fire
may result. For your safety, follow the installation
instructions. Never use make-shift compromises
during the installation of this heater. Contact local
building or fire officials about permits, restrictions
and installation requirements in your area.
MODEL: 2500(L)(LN)
SAVE THESE INSTRUCTIONS
United States Stove Company
227 Industrial Park Road
South Pittsburg, TN 37380
Report#: 215-S-23-2
Certified to: UL1482 and Certified to: ULC S627-00
MOBILE HOME APPROVED (U.S. ONLY)
U.S. Environmental Protection Agency
Certified to comply with 2015 particulate
emissions standards.
851710J-0904H

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2500L and is the answer not in the manual?

Questions and answers

Summary of Contents for Country Hearth 2500L

  • Page 1 Owner’s Operation and Instruction Manual MODEL: 2500(L)(LN) SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. CAUTION! Please read this entire manual before you install or use your new room heater.
  • Page 2: Optional Accessories

    The instructions pertaining to the installation of your wood stove comply with UL-1482 and ULC-S627 standards. This manual describes the installation and operation of the Country Hearth, 2500(L)(LN) wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015.
  • Page 3: Tools And Materials Needed For Installation

    TOOLS AND MATERIALS NEEDED FOR INSTALLATION You will need a drill with a 1/8” bit to install sheet metal screws into connector pipe. A 5/16” socket/wrench or screw driver to install pedestal trim, room air deflector, and blower assembly described below. A 1/2” socket/ wrench to install flue collar.
  • Page 4: Installation

    ASSEMBLY INSTRUCTIONS Blower Assembly THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION. THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE. DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES! Step 1.
  • Page 5: Floor Protector

    FLOOR PROTECTOR Your wood stove should be placed on a 1 inch, non-combustible surface with a k factor of 0.84. For multiple layers, add R-values of each layer to determine the overall R-value. The R value for the required board is 1.2. If there is a horizontal section of chimney connector, the floor protector should go under it and 2 inches beyond each side Convert specification to R-value:...
  • Page 6: Chimney Connector (Stove Pipe)

    CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draft. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021”...
  • Page 7: Factory Built Chimney

    FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass- through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer.
  • Page 8: Masonry Chimney

    MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed.
  • Page 9: Combustible Wall Chimney Connector Pass-Throughs

    COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS Method A. 12” (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent.
  • Page 10: Outside Combustion Air

    OUTSIDE COMBUSTION AIR Your wood stove is approved to be installed with an outside air intake which is necessary for a mobile home. This type of installation is also required in air tight houses and houses with negative pressure problems. You can purchase this option through your heater dealer.
  • Page 11 WOODSTOVE UTILIZATION This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT BURN: 1. Garbage; 10.
  • Page 12: Operational Tips

    It is EXTREMELY IMPORTANT that you use DRY WOOD only in your wood stove. The wood should have dried for 9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is very important to keep in mind that even if the wood has been cut for one, two or even more years, it is not necessarily dry, if it has been stored in poor conditions.
  • Page 13 When you have achieved a good bed of hot embers, we recommend the following burn procedures: Burn Rate Adjust Damper from fully closed Burn Time Blower Speed 1/32” (1mm) @ 30 minutes Medium - Low 1/16” (1.5mm) @ 30 minutes Medium - High 5/16”...
  • Page 14: To Prevent Creosote Build Up

    RELOADING Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few seconds prior to opening the stove’s door. Then proceed by opening the door very slowly;...
  • Page 15: Maintenance

    SMOKE AND CO MONITORS Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when exposed to elevated concentrations for extended periods of time. While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or confined areas can be dangerous.
  • Page 16: Repair Parts

    REPAIR PARTS In order to maintain warranty, components must be replaced using original manufacturers parts purchased through your dealer or directly from the appliance manufacturer. Use of third party components will void the warranty. Key Part No. Description Qty. 40292A 6”...
  • Page 17 REPAIR PARTS Part No. Description Qty. 891135 Spring Handle - Lg 25692 Handle 83506 3/8 X 1-1/4 Roll Pin 25491 Feed Door 40770 Feed Door (for LN) 88066 Gasket, 5/8 Rope (Ld2 .625 G) 4.6 ft 88087 Glass Gasket (1 X 3/16) 4 ft 891131 Ceramic Glass...
  • Page 18: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider: Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 19 Limited Warranty The operation of this unit in a manner inconsistent with the owner’s manual instructions; (7) installation or use of components not supplied with appliance will void the warranty and is also against federal regulations. United States or any other components not expressly authorized and approved by USSC; (8) Stove Company warrants this product to be free from defects in material and modification of the appliance not expressly authorized and approved by USSC workmanship, to the original retail purchaser only, for the time period identified...
  • Page 20 HOW TO ORDER REPAIR PARTS / COMMENT COMMANDER DES PIÈCES DÉTACHÉES This manual will help you obtain efficient, dependable service from your heater, and enable you to order repair parts correctly. Keep this manual in a safe place for future reference. When writing, always give the full model number which is on the nameplate attached to the heater.

This manual is also suitable for:

2500ln

Table of Contents

Save PDF