Page 1
MeacoCool MC Series Portable Air Conditioner Instruction Manual MeacoCool MC Series 12000BTU and 14000BTU (Cooling Only) and (Cooling and Heating) Portable Air Conditioners Please read this instruction manual before using the portable air conditioner and keep safe for future reference.
If in doubt do not use the portable air conditioner and consult a qualified electrician or a Meaco approved engineer. Keep Air Intakes Clear: Do not clog or block the air intakes by placing the portable air conditioner too close to curtains, walls or anything that will restrict the air inlet.
Page 3
Do not puncture either during the units working life or after. At the end of life dispose of following local recycling regulations. • If there is any damage to the portable air conditioner then do not use it and contact Meaco or your retailer. •...
GREEN/YELLOW. Always ensure that the cord grip is positioned and fastened correctly. Only ever use the same fuse as fitted in the original product, if in doubt please contact Meaco first, or a qualified electrician. Example wiring for a Standard British Plug:...
2 window kits and window kit screws. If at any point certain parts are damaged or lost, replacement parts are available to purchase at www.meaco.com. Control panel...
GENERAL ADVICE ----------------------------------------------------------------------------------------------------------------------------- ---------- • Before putting your portable air conditioner into operation for the first time, the instruction manual should be studied carefully. • After receiving the portable air conditioner, you should check the unit for any transport damage. In case of damage, you should inform the sender immediately.
Page 7
SET UP --------------------------------------------------------------------------------------------------------------------------------------- The portable air conditioner needs to be vented to the outside in order to remove hot air, this is typically done through a window. The duct provided is 1.8 metres long and cannot be extended. There are two different window kits provided: the window kit plates and the flexible window kit – only one window kit needs to be used depending on the type of window/door you wish to use.
Page 8
• Connect the duct to section B. • After completing the assembly, fit and adjust sections A and C depending on the length you require, using the window kit screws provided. Plate A: 65cm Plate B: 65cm Plate C: 51cm Total combined: 170cm Please note the diagram is schematic drawing for reference only.
Page 9
Step 5: Attach the duct via the air exhaust on the portable air conditioner using the duct machine adaptor. * Whilst cooling, do not remove this bung. This is the water revisor where water sits until it is evaporated out via the duct. Step 6: Extend the duct to the desired length avoiding any bends or kinks in the hose.
CONTROL PANEL ----------------------------------------------------------------------------------------------------------------------------- ---------- Please note the Heat LED will only show on the display if you have a CH (Cooling and Heating) model. POWER BUTTON When first plugged in the portable air conditioner will enter standby mode. All lights on the display will turn on for one second and then switch off (apart from the Power Button which will continuously stay lit up).
THE MODES ----------------------------------------------------------------------------------------------------------------------------- ---------- COOL MODE 1. Press the Mode Button until the LED light next to Cool on the display appears. Press the Up and Down arrows to adjust the temperature displayed. The temperature can be set between 16°C and 32°C The portable air conditioner will run until the desired temperature is reached.
HEAT MODE (only available on CH models) 1. Press the Mode Button until the LED light next to Heat on the display appears. Press the Up and Down arrows to adjust the temperature displayed. The temperature can be set between 16°C 32°C The portable air conditioner will run until the desired temperature...
OTHER FUNCTIONS ----------------------------------------------------------------------------------------------------------------------------- ---------- THE TIMER The timer has two modes of operation and can be set anywhere between 1-24 hours: Off Timer and On Timer. • To set the Off Timer, when the portable air conditioner is turned on, press the Timer Button. Use the Up and Down arrows to set the number of hours in which you want the portable air conditioner to turn off.
REMOTE CONTROL ----------------------------------------------------------------------------------------------------------------------------- ---------- COOLING MODEL ONLY COOLING AND HEATING (CH) MODEL Cool Mode Power Heat Mode Dry Mode Speed Button Up Arrow Fan Mode Down Arrow Lourve Button Sleep Mode Timer Change between °C and °F...
Page 15
DRAINAGE ----------------------------------------------------------------------------------------------------------------------------- ---------- When the portable air conditioner is used in Dry Mode or Heat Mode the drainage hose needs to be attached continuously in order to remove any collected water (Diagram 1). When the portable air conditioner is used in Cool Mode the drainage hose does not need to be attached continuously.
Page 16
Diagram 2 Securely attach the drainage hose to the outlet.
CLEANING AND STORAGE ----------------------------------------------------------------------------------------------------------------------------- ---------- The air filters must be cleaned a minimum of once every two weeks. Dust will collect on the filters restricting its airflow. The restricted airflow will reduce the efficiency of the system and if it becomes blocked, it can cause damage to the portable air conditioner.
Press the ON/OFF button. been pressed. If it still does not work please Power button does not work Check the instructions above. contact Meaco. The compressor does not turn Machine turned on but on for the first three minutes of Wait three minutes.
Page 20
Please contact Meaco. Temperature sensor is faulty. Please contact Meaco. Evaporator coil sensor is faulty. Please contact Meaco. If you need to contact Meaco, please use the contact details below. Contact Number: 01483 234900 Contact Email: customerservice@meaco.com service@meaco.com Live Chat:...
8. All claims for compensation, including consequential damage, will not be entertained. To prevent unnecessary expenses, we recommend that you always carefully read the user’s manual first. If this does not provide a solution, please call Meaco and we will be happy to help. This portable air conditioner has been...
Page 22
This marking indicates that this product should not be disposed with other household wastes throughout the UK and EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
Need help?
Do you have a question about the MC Series and is the answer not in the manual?
Questions and answers