Download Print this page

Whirlpool AKT 617 Product Description Sheet

Advertisement

Quick Links

AKT 617
GB
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
5019 319 01789
PRODUCT DESCRIPTION SHEET
Removable panstand grids
1.
Auxiliary burner
2.
Semi-rapid burner
3.
Semi-rapid burner
4.
Ultra-rapid burner
5.
Auxiliary burner control knob
6.
Semi-rapid burner control knob
7.
Semi-rapid burner control knob
8.
Ultra-rapid burner control knob
9.
SYMBOLS
Tap closed
Maximum flame
Minimum flame
.
Burner
Pot Ø
ultra-rapid
from 24 to 26 cm
semi-rapid
from 16 to 22 cm
auxiliary
from 8 to 14 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE
Type of gas used
Type of
Ø injector
burner
ultra-rapid
136
NATURAL GAS
semi-rapid
95
(Methane)
G20
auxiliary
78
LIQUID
ultra-rapid
94
PETROLEUM GAS
semi-rapid
67
50
auxiliary
(Butane-Propano)G30-G31
Type of gas
Configuration
Rated thermal
used
model
flow rate kW
G20 20 mbar
4 burners
G30-G31 30 mbar
4 burners
ELECTRIC SUPPLY: 230 V ~ 50 Hz
CZ
SK
RU
CATEGORY II2H3B/P
Rated thermal
Rated
Reduced heat
Gas pressure (mbar)
flow rate kW
consumption
capacity kW
min.
3.50
333 l/h
0.60
1.65
157 l/h
0.35
1.00
95 l/h
0.30
3.50
254 g/h
0.60
1.65
120 g/h
0.35
1.00
73 g/h
0.30
Total rated
Air necessary (m
consumption
combustion of 1 m
7.80
742 l/h
7.80
567 g/h
RO
UA
rat.
max.
17
20
25
25
30
35
3
) for the
3
of gas
9.52
30.94

Advertisement

loading

Summary of Contents for Whirlpool AKT 617

  • Page 1 AKT 617 PRODUCT DESCRIPTION SHEET Removable panstand grids DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm) Auxiliary burner Semi-rapid burner Semi-rapid burner Ultra-rapid burner Auxiliary burner control knob Semi-rapid burner control knob Semi-rapid burner control knob Ultra-rapid burner control knob SYMBOLS...
  • Page 2 Whirlpool and equipped with a cooling system. The manufacturer declines all liability if another brand oven is installed beneath the Product hob.
  • Page 3 INSTALLATION Top 40 mm Position the hob in the worktop opening made respecting the dimensions indicated in the Product Description GAS CONNECTION Sheet. • The gas supply system must comply with local regulations. Note: the power supply cable must be long enough to Top 30 mm •...
  • Page 4 Manufacturer: Note: to avoid damaging the electric ignition device, do not use it when the burners are not in their housing. Whirlpool Europe S.r.l. Viale G. Borghi, 27 21025 Comerio (VA)