Item
B-Band
9) Frequency: 430.050MHz
Mode: FM(3kHz)
SSG: -121dBm(0.19μV)
AF output: 0.63V/8 ohm
ATT:OFF
10) Frequency: 430.050MHz
Mode: FM(3kHz)
SSG: -115.5dBm (0.375μV)
AF output: 0.63V/8 ohm
ATT:ON
11) Frequency: 80.200MHz
Mode: WFM(75kHz)
SSG: -102dBm(1.77μV)
AF output: 0.63V/8 ohm
12) Frequency: 118.050MHz
Mode: AM 60%
SSG: -112dBm(0.562μV)
AF output: 0.63V/8 ohm
3.Squelch
1) Frequency: 145.950MHz
A-Band
SQL :Level1
Mode: FM(3kHz)
SSG: -122dBm(0.178μV)
2) SSG: OFF
3) Frequency: 439.950MHz
SQL :Level1
Mode: FM(3kHz)
SSG: -122dBm(0.178μV)
4) SSG: OFF
B-Band
5)Frequency: 145.950MHz
SQL :Level1
Mode:FM(3kHz)
SSG: -119dBm(0.25μV)
6) SSG: OFF
7)Frequency: 223.550MHz
SQL :Level1
Mode:FM(3kHz)
SSG: -119dBm(0.25μV)
8) SSG: OFF
9)Frequency: 439.950MHz
SQL :Level1
Mode:FM(3kHz)
SSG: -119dBm(0.25μV)
10) SSG: OFF
11)Frequency: 51.100MHz
SQL :Level1
Mode:FM(3kHz)
SSG: -118dBm(0.28μV)
12) SSG: OFF
1-42 (No.RA044<Rev.001>)
Condition
Test-
equipment
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
SSG
Oscilloscope
Measurement
Unit Terminal Unit Parts Method
ANT
SP
ANT
SP
ANT
SP
ANT
SP
ANT
ANT
ANT
ANT
ANT
ANT
ANT
ANT
ANT
ANT
ANT
ANT
Adjustment
Specifications
/Remarks
Check
12dB SINAD or more
Check
12dB SINAD or less
Check
12dB SINAD or more
Check
10dB S/N or more
Check
Open Squelch
Check
Close Squelch
Check
Open Squelch
Check
Close Squelch
Check
Open Squelch
Check
Close Squelch
Check
Open Squelch
Check
Close Squelch
Check
Open Squelch
Check
Close Squelch
Check
Open Squelch
Check
Close Squelch

Hide quick links: