Item
Condition
HF-Band
6)Frequency: 51.100MHz
SQL Level1
SSG:-121dBm(0.2μV)
S-1
SSG:-116dBm(0.35μV)
S-FULL
SSG: -101dBm(2μV)
Mode: FM(3kHz)
4.10 Receiver Section: User Mode Confirmation Items
Item
1.Sensitivity
1) Frequency: 145.950MHz
A-Band
Mode: FM(3kHz)
SSG: -121dBm(0.19μV)
AF output: 0.63V/8 ohm
ATT:OFF
2) Frequency: 145.950MHz
Mode: FM(3kHz)
SSG: -115.5dBm (0.375μV)
AF output: 0.63V/8 ohm
ATT:ON
3) Frequency: 430.050MHz
Mode: FM(3kHz)
SSG: -120dBm(0.22μV)
AF output: 0.63V/8 ohm
ATT:OFF
4) Frequency: 430.050MHz
Mode: FM(3kHz)
SSG: -115.5dBm (0.375μV)
AF output: 0.63V/8 ohm
ATT:ON
B-Band
5) Frequency: 144.050MHz
Mode: FM(3kHz)
SSG: -119dBm(0.25μV)
AF output: 0.63V/8 ohm
ATT:OFF
6) Frequency: 144.050MHz
Mode: FM(3kHz)
SSG: -115.5dBm (0.375μV)
AF output: 0.63V/8 ohm
ATT:ON
7) Frequency: 224.950MHz
Mode: FM(3kHz)
SSG: -119dBm(0.25μV)
AF output: 0.63V/8 ohm
ATT:OFF
8) Frequency: 224.950MHz
Mode: FM(3kHz)
SSG: -115.5dBm (0.375μV)
AF output: 0.63V/8 ohm
ATT:ON
Test-
equipment
SSG
Condition
Test-
equipment
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
SSG
Audio analyzer
Oscilloscope
Measurement
Unit
Terminal
Unit
ANT
Measurement
Unit Terminal Unit Parts Method
ANT
SP
ANT
SP
ANT
SP
ANT
SP
ANT
SP
ANT
SP
ANT
SP
ANT
SP
Adjustment
Specifications
/Remarks
Parts
Method
[] or
Write
[Write]
Adjustment
Specifications
/Remarks
Check
12dB SINAD or more
Check
12dB SINAD or less
Check
12dB SINAD or more
Check
12dB SINAD or less
Check
12dB SINAD or more
Check
12dB SINAD or less
Check
12dB SINAD or more
Check
12dB SINAD or less