en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts
2.1.2

Description

Chapter 2 details how to install an AutoDome Pendant Arm to a wall, a corner, or to a mast
(pole). Any variations to the installation procedures are noted.
Refer to Section 3 Installing Roof Parapet and Pipe Mounts for a Roof (Parapet) or Pipe mount
installation or Section 4 Installing the In-Ceiling Mount for an In-Ceiling mount installation.
2.1.3

Tools Required

2.2

Pre-installation Checklist

1.
2.
WARNING!
Power and I/O cabling must be routed separately inside different permanently earthed metal
conduits.
3.
4.
WARNING!
Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
5.
F.01U.217.818 | 1.0 | 2011.04
5 mm Allen wrench (supplied)
Small, straight-blade screwdriver - 2.5 mm (0.1 in.)
No. 2 Phillips screwdriver
Socket wrench and 9/16-in. socket
Banding tool (Bosch P/N TC9311PM3T) - if installing a mast (pole) mount
3/4 in. (20-mm) NPS right angle conduit connector - if installing a mast (pole) mount with
a VG4-ARMPLATE
Determine the location and distance for the Power Supply Box based on its voltage and
current consumption.
You may choose to route the main power supply through an intermediate VG4 power
supply box (VG4-PSU1 or VG4-PSU2) before connecting the power to the pendant arm
power supply box (VG4-PA0). Refer to Section 5 Cable and Wire Standards, page 61, for
wiring information and distances.
Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to
ensure that water cannot enter the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
Route all rough wiring including: power, control, video coax, alarms I/O, relay I/O, and
fiber optic cabling. Refer to Section 5 Cable and Wire Standards, page 61, for video and
control protocol methods.
If you plan to use the RS232 or RS485 protocol to control the AutoDome, refer to
Section 5.4.2 Controlling the AutoDome via the RS232 Protocol, page 64, or to
Section 5.4.3 Controlling the AutoDome via the RS485 Protocol, page 65, for instructions on
configuring the AutoDome to accept these protocols.
Choose the appropriate AutoDome model (indoor or outdoor) for the environment in
which it will be used.