Bosch VG5 600 Series Installation Manual
Bosch VG5 600 Series Installation Manual

Bosch VG5 600 Series Installation Manual

Autodome 600 series analog ptz camera
Hide thumbs Also See for VG5 600 Series:
Table of Contents

Advertisement

AutoDome 600 Series Analog PTZ
Camera
VG5 600 Series
en
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VG5 600 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bosch VG5 600 Series

  • Page 1 AutoDome 600 Series Analog PTZ Camera VG5 600 Series Installation Manual...
  • Page 3: Table Of Contents

    Installing the VG4-A-9543 Pipe Mount Wire the Pipe Interface Board 3.7.1 Wiring for Multiple AutoDomes 3.7.2 Connecting Wires to the Pipe Interface Board Prepare Pendant for Installation Attach Pendant to Pipe and Tighten Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 4 Configuring Non-supervised Alarms (inputs 1 through 7) 6.3.1 Configuring a Normally Open Non-supervised Alarm 6.3.2 Configuring a Normally Closed Non-supervised Alarm Alarm Outputs 6.4.1 Configuring a Dry Contact Relay 6.4.2 Configuring an Open Collector Output F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 5 Bubble Handling and Cleaning Handling Cleaning 7.2.1 Cleaning the Bubble Interior 7.2.2 Cleaning the Bubble Exterior Installation Notes for AutoTracker Camera Height Mount/Mounting Surfaces Field of View Unwanted Motion Index Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 6: Safety

    ON/OFF switch is in the ON position. The power cord is the main power disconnect device for switching off the voltage for all units. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 7 17. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
  • Page 8: Safety Precautions

    -10 °C (14 °F) to 50 °C (122 °F). Camera signal - Protect the cable with a primary protector if the camera signal is beyond 140 feet, in accordance with NEC800 (CEC Section 60). F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 9 Please dispose of these units at an environmentally compatible recycling facility, per European Directive 2002/96/EC. Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible.
  • Page 10 Because the ISDN circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the Telephone Network Voltage (TNV) circuits. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 11 UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING- RELATED FUNCTIONS OF THIS PRODUCT. Copyright This user guide is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 12: Customer Support And Service

    | Safety AutoDome 600 Series Analog PTZ Camera Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers Telephone: 800-366-2283 or 585-340-4162 Fax: 800-366-1329 Email: cctv.repair@us.bosch.com...
  • Page 13: Installing The Pendant Arm Wall, Corner, And Mast (Pole) Mounts

    Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. Refer to Section 1.4 Customer Support and Service, page 12, for contact information.
  • Page 14: Description

    No. 2 Phillips screwdriver – Socket wrench and 9/16-in. socket – Banding tool (Bosch P/N TC9311PM3T) - if installing a mast (pole) mount – 3/4 in. (20-mm) NPS right angle conduit connector - if installing a mast (pole) mount with a VG4-ARMPLATE...
  • Page 15: Mount Power Supply Box

    A stud diameter of 6.4 mm (1/4 inch) to 8 mm (5/16 inch) able to withstand a 120 kg (265 lb) pull-out force is recommended. The mounting material must be able to withstand this pull out force. For example, 19-mm (3/4-inch) minimum for plywood. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 16: Route Wires And Attach Connectors

    3 mm must be incorporated. CAUTION! A VG5 600 Series AutoDome installation using coaxial cable to transmit video, either through a direct coaxial connection or through a fiber optic module, requires that you use the coaxial cable with ferrite shipped with the AutoDome pendant.
  • Page 17: Coaxial Cable Connections

    Make the Connections J102 24 VAC P101 (LED) P106 P105 GND T XD R XD C+ C- GND T XD R XD C+ C- Figure 2.3 Pendant Arm Power Supply Box Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 18 If “daisy chaining” a series of AutoDomes, a terminating resistor is required in the last dome of the series. The Bosch Power Supply Box is supplied with a 100 Ω terminating resistor located between the Biphase terminals C- and C+ (pins 1 and 2) of the P106 control connector.
  • Page 19 Connector to the appropriate incoming wires. Refer to Figure 2.4, Page 19, above, for the wire connections. Refer to Section 6 Alarms and Relay Connections, page 76 for more details about wiring alarms and relays. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 20: Power Supply Box Connections

    T 5.0 A T 2.0 A T 3.15 A 115 V T 1.6 A T 2.0 A T 3.15 A 230 V T 0.8A T 2.0 A T 3.15 A F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 21: Route Power Through Intermediate Power Supply Box

    – The main power supply connected to the P101 connector and to the grounding screw. – The 24 VAC power out wire connected to the P107 heater power connectors. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 22 Ground Grounding Screw P101 115/230 VAC Power In Line Neutral P107 24 VAC Power Earth Heater Heater Ground (24 VAC) (24 VAC) Table 2.2 VG4-PSU1/VG4-PSU2 Power Supply Box Connections F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 23 Cut and trim the 24 VAC power and ground wires with sufficient slack to reach their connector terminal in the box, but not so long as to be pinched by or to obstruct closing the cover door. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 24 Ground Wire P101 Connector Control Data and Video In/Out Wires Follow the instructions in Section 2.6 Attach Pendant Arm to Power Supply Box, page 25, to continue the installation. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 25: Attach Pendant Arm To Power Supply Box

    Serious injury or death can occur if the hinge pins of the Pendant Arm are not fully engaged (locked) to the Power Supply Box. Exercise caution before releasing the Pendant Arm. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 26: Make Connections In Power Supply Box

    24 VAC Power UTP Video/Ethernet (Ethernet for VG5 700 Series only) Alarm Inputs Alarm Outputs Relays Grounding Strap WARNING! Do not connect the RJ45 connector unless using UTP video or Ethernet. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 27: Installing The Vg4-A-Armplate

    Secure the Corner Plate to the wall corner using four (4) studs (not included). Secure the Mounting Plate to the Corner Plate using the four (4) 3/8 x 1-3/4-inch bolts and split lock washers (supplied). Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 28 Follow the instructions provided with the banding tool to securely mount the Mast Plate to the pole. Contact your Bosch Sales Representative to order Banding Tool P/N TC9311PM3T.
  • Page 29: Attach The Pendant Arm To The Mounting Plate

    Once you have the hinges aligned, release the top hinge pin to engage its mating hinge on the Mounting Plate. Then release the bottom hinge pin from the Hinge Pin Stop to lock the Pendant Arm to the Mounting Plate. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 30: Route And Connect Wires To A Power Supply Box

    Grounding Strap (black) UTP Video/Ethernet (blue) (Ethernet for VG5 700 Series only) 24 VAC Power (red) Alarm Outputs (white) Relay Contacts (yellow) Alarm Inputs (gray) Coax Video (black) Serial Communications (green) F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 31 Refer to Section 5 Cable and Wire Standards, page 67, for the different methods of transmitting video and control protocols, and wire specifications. Note: Do not connect the RJ45 connector unless using UTP video. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 32: Prepare Pendant For Installation

    Insert a small (2 mm) straight blade screw driver into the bubble release opening in the bubble trim-ring to release the lock, and then remove the screwdriver. See the figure below. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 33 Re-insert the Bubble assembly into the Pendant housing, and rotate it clockwise (looking down at the dome) until it locks. The latch mechanism makes a click when it locks. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 34: Attach Pendant To Arm And Tighten

    Hook and drop. 2a Recessed Hinge Pin 2b Dome Connector Rotate down to engage dome connector. Tighten the two (2) mounting screws to a minimum torque of 10-12 N-m (90-105 in.-lbs). F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 35 10-12 N-m (90-105 in.-lbs). CAUTION! You must tighten the two mounting screws to a minimum torque of 10-12 N-m (90-105 in.-lbs) to ensure a proper seal between the arm and the housing. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 36: Installing The Roof Parapet And Pipe Mounts

    The VG4-A-9230 Series are stationary mounts intended for rooftop parapet vertical walls. They are made of light weight aluminum with a corrosion-resistant finish and are used for all Bosch AutoDome Cameras up to a rated load of 29 kg (64 lb). These mounts can be fitted to the inside or outside of parapet walls and can swivel for ease of positioning and for servicing the AutoDome.
  • Page 37: Pre-Installation Check List

    Purchase the appropriate mounting hardware to use, depending on the location of the AutoDome and the application. CAUTION! Select a rigid mounting location to prevent excessive vibration to the AutoDome camera. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 38: Mount Power Supply Box

    Attach the 3/4 in. (20 mm) watertight pipe fittings (not supplied) to the holes of the Power Supply Box through which you will run the power, video, and control data wires. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 39: Attach Cover Door

    After all wiring is complete, close the cover door and tighten the two (2) captive screws on the cover door to 10-12 N-m (90-105 in.-lbs) to ensure the Power Supply Box is watertight. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 40: Route Wires And Attach Connectors

    120 VAC/230 VAC Power In Coax, UTP Video, or Ethernet Wire (Ethernet for VG5 700 Series only) P101 Connector Control Wire Ground Connection 24 VAC Power Out Transformer P107 Connector F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 41 Heater Power NOTICE! Fiber Optic Models require that the Biphase control wires be routed from the Power Supply Box P106 connector out to the Pipe Interface Board P105 connector. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 42: Wiring The Power Supply Box

    Refer to connector P107 in Table 3.1, Page 45. NOTICE! All video, control, and alarm wires either pass through the Power Supply Box or by-pass it and connect directly to the Pipe Interface Board. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 43: Wiring The Fiber Optic Model

    (6) pin control data connector to the wires in the Power Supply Box. (GND) NC 24V GND TXD RXD C+ C- Transformer In/Out BNC to Dome ST Connector (Fiber) In/Out Power In From Arm Harness Data In/Out Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 44: Power Supply Box Connections

    T 5.0 A T 2.0 A T 3.15 A 115 V T 1.6 A T 2.0 A T 3.15 A 230 V T 0.8A T 2.0 A T 3.15 A F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 45: Installing The Vg4-A-9230 Roof Parapet Mount

    Parapet arm for the AutoDome to clear the top of the wall when it is swung into position. Provide enough slack in the wires to rotate the pipe arm over the roof and back when camera maintenance is required. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 46 If attaching the parapet mount to a flat roof, attach the optional LTC 9230/01 Roof Mount Plate to the roof and then attach the Parapet Wall Bracket to the Roof Mount Plate. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 47 Make sure all surfaces are clean and dry. – Apply a bead of sealant completely around the leading threads of the male fitting. – Force the adhesive into the threads to thoroughly fill all voids. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 48 1/4-inch stainless steel eye bolt (not supplied). Loop the guy-wire through the eye bolt and attach both ends to anchor spots on the roof. Refer to Figure 3.7, Page 47. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 49: Installing The Vg4-A-9543 Pipe Mount

    Figure 3.9, Page 49. WARNING! You must thread the Dome Cap onto the pipe until it is tight. Failure to do so can result in damage or serious injury or death. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 50: Wire The Pipe Interface Board

    Board, as illustrated below. Refer to Section 5 Cable and Wire Standards, page 67 for cable and wiring recommendations and specifications. AGND OUT 3 OUT 2 OUT 1 Figure 3.10 Pipe Interface Board Connections F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 51: Wiring For Multiple Autodomes

    If using UTP for video, attach an RJ45 connector plug to the UTP cable and connect the plug to its mating connector J101 on the Pipe Interface Board. WARNING! Do not connect the RJ45 connector unless using UTP video. This connection causes video distortion. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 52 Alarm Out 3‡ Alarm In 5 Alarm Out 4 Normally Closed Alarm Ground Alarm In 6 Earth Ground Alarm In 7 Analog Alarm 1 Alarm Ground Analog Alarm 2 Ground F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 53: Prepare Pendant For Installation

    Insert a small (2 mm) straight blade screw driver into the bubble release opening in the bubble trim-ring to release the lock, and then remove the screwdriver. See the figure below. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 54 Re-insert the Bubble assembly into the Pendant housing, and rotate it clockwise (looking down at the dome) until it locks. The latch mechanism makes a click when it locks. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 55: Attach Pendant To Pipe And Tighten

    2a Dome Cap 2b Recessed Hinge Pin Dome Connector Rotate down to engage dome connector Tighten the two (2) mounting screws to a minimum torque of 10-12 N-m (90-105 in.-lbs) Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 56: Make Connections In The Power Supply Box

    BNC connector of the Fiber Optic Module. Connect the six (6) control plugs from the dome, installed previously, to the P106 control I/O connector in the Power Supply Box. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 57: Installing The In-Ceiling Mount

    Verify that all the parts listed in the product's Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. Refer to Section 1.4 Customer Support and Service, page 12, for contact information.
  • Page 58: Pre-Installation Check List

    Section A Installation Notes for AutoTracker, page 82, before mounting the AutoDome. Dimensions 176.8 DIA. 6.96 210.7 8.30 150.2 5.91 19.0 94.0 0.75 3.70 153.9 6.06 204.3 8.04 inches Figure 4.1 In-ceiling Dimensional Outline F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 59: Prepare Drywall Ceiling For Installation

    Use the bracket Base Plate as a template or cut a 7 in. hole with a tolerance of ±1/8 in. (177.8 mm ±2.2 mm) hole in the center of the ceiling tile with a drywall utility saw or Jig Saw. Figure 4.3 Cut Hole in Ceiling Tile Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 60: Wire The Interface Box

    If installing the dome to a drywall ceiling, allow enough wire to make the connections in the Interface Box below the ceiling. Refer to Figure 4.7, for connector locations and Table 4.1, Page 63, for wire connections. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 61 Secure the lid to the Interface box by pushing the lid down until the clip on the lid catches against the box. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 62: Interface Box Connections

    The following figure is a detailed illustration of the In-ceiling Interface box. Figure 4.7 In-ceiling Interface Box Fiber Optics Coax Video UTP/Ethernet Video Alarm In (Ethernet for VG5 700 Series only) Dome Power Analog In Data In/Out Relay F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 63: Prepare Bubble

    Section 5.4.2 Controlling the AutoDome via the RS232 Protocol, page 71, or Section 5.4.3 Controlling the AutoDome via the RS485 Protocol, page 72, for instructions. Then, proceed to the next step. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 64: Attach Housing To The Interface Box

    Insert the In-ceiling housing through the hole in the ceiling to verify that the edge of the hole support the unit. Then remove the housing from the hole. Align the ball studs of the In-Ceiling Housing to the Stud Retainers on Interface Box and attach. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 65 Figure 4.12, Page 66, below for an illustration of this process. Bosch Security Systems, Inc. Installation Manual...
  • Page 66: Secure Housing To Ceiling

    Over torquing the Ceiling Clamps can damage the clamp or ceiling. Only tighten the clamp until it contacts the ceiling and you start to feel some resistance. If using a power screwdriver, set the torque level to the lowest setting. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 67: Cable And Wire Standards

    Bilinx control data can also be sent over the same cable. Bilinx is a Bosch 2-way communication protocol that allows remote control, configuration, and updates over a video coax cable. Bilinx is available on all VG5 100 and 600 Series AutoDomes.
  • Page 68: Using Utp To Transmit Video And Control

    Bilinx control data can also be sent over the same two video wires (1 & 2). Bilinx is a Bosch 2- way communication protocol that allows remote control, configuration and updates over a passive UTP cable.
  • Page 69: Using Multi-Mode Fiber Optic To Transmit Video And Control

    Controlling the AutoDome via Biphase (Shielded 2-wire, half-duplex, multi-drop, 5000 ft. cable limit) Biphase is the standard Bosch protocol used to send Pan/Tilt/Zoom control over 2-wire shielded twisted pair (STP) terminated with a 100 Ω terminal resistor. The AutoDome has a 100 Ω termination resistor between the Biphase C+ and C- terminals.
  • Page 70 C- (Biphase) Dome 3 C+ (Biphase) Dome 2 Earth Ground Dome 1 Head End Biphase C- (Biphase) Signal Ground C + (Biphase) Last Dome Data In/Out Shield P105/P106 Connector F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 71: Controlling The Autodome Via The Rs232 Protocol

    Slide Switch Away from LEDs (factory default) Figure 5.4 Connections for RS232 Operation C- (Biphase) AutoDome Data In/Out C+ (Biphase) P105/P106 Connector Earth Ground Head End RS232 Signal Ground Ground Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 72: Controlling The Autodome Via The Rs485 Protocol

    LEDs (default). CAUTION! Bosch recommends that multiple RS485 connections be arranged as a connected series of point-to-point (multi-dropped) nodes, as a line or as a bus. It is not recommended to arrange RS485 connections as a star, ring, or as a multiple-connected network. Star and ring topologies may cause signal reflections or excessively low or high termination impedance.
  • Page 73: Fiber Optic Module With An Rs232/Rs422 Controller

    To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 controller you must run control wires from the controller to an LTC 4629 head-end fiber optic module. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 74: Connecting To An Ltc 4629 Head End Data/Video Transceiver

    P105 GND TXD RXD C+ C- GND TXD RXD C+ C- Figure 5.8 Detail of P106 Connections Green RxD wire connected to C+ Blue Ground wire connected to C- F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 75 Switch Location LEDs Move Switch to the left for RS232 Operation CPU Module 11. Return the bubble to the AutoDome housing. 12. Return power to the power supply box. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 76: Alarms And Relay Connections

    Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the AutoDome. 2.2K Figure 6.1 N.O.S. - Normally Open Supervised Connections Dry Contact Dome Connector Alarm 1 or 2 only (Pin 5 or 6) Ground (Pin 7) F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 77: Configuring A Normally Closed Supervised Alarm

    From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input # to N.C.S. See the table below for contact and condition details. AutoDome Programmed N.C.S. Contact Alarm Condition Open Alarm Closed Normal Short Tamper Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 78: Configuring Non-Supervised Alarms (Inputs 1 Through 7)

    From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input # to N.C. See the table below for contact and condition details. AutoDome Programmed N.C. Circuit Alarm Indication Open Alarm Closed Normal F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 79: Alarm Outputs

    @ 150 ma. Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the transistor. Connect the appropriate stripped wire to the ground (GND) connector. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 80: Bubble Handling And Cleaning

    Figure 7.1 Pendant Bubble Release Opening Firmly rotate the bubble counterclockwise approximately 20 degrees until the bubble assembly releases from the Pendant Housing. F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 81: Cleaning The Bubble Exterior

    Do Not scrape the bubble with razor blades or other sharp instruments. – Do Not use Benzene, Gasoline, Acetone, or Carbon Tetrachloride on the bubble. – Do Not clean bubbles in the hot sun or on very hot days. Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 82: A Installation Notes For Autotracker

    The height of the AutoDome determines the maximum effective distance that the AutoTracker can track an individual. Bosch recommends a minimum camera height of 3.6 m (12 ft). It is also important to note that the AutoDome will not tilt above the horizon when tracking.
  • Page 83 Use the Virtual Masking feature (refer to the VG5 Series AutoDome User’s Manual) to mask unwanted motion from trees or cars. – Bosch recommends that you draw the virtual mask 10% larger than the object to be masked. – Avoid neon lights, flashing lights, night time lights, and reflected light (from a window or mirror, for example).
  • Page 84 14 copper wire 67 for roof parapet or pipe mount 37 corner installation 16 27 non-supervised alarms 78 corner plate 16 cover door 39 F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.
  • Page 85 60 for pendant arm, corner or mast mount 16 for roof parapet or pipe mount 40 RS232 71 RS485 72 supervised 76 suspension ceiling 59 Bosch Security Systems, Inc. Installation Manual F.01U.265.793 | 2.0 | 2012.02...
  • Page 86 | Index AutoDome 600 Series Analog PTZ Camera F.01U.265.793 | 2.0 | 2012.02 Installation Manual Bosch Security Systems, Inc.

Table of Contents