Download Print this page

Hitachi SJ-PB2 Instruction Manual page 40

Profibus-dp communication board for sj700/sj300/l300p series inverter

Advertisement

APPENDIX PARAMETER OBJECT LISTS
Code PNU Size
b034
129
2
b051
130
2
b052
131
2
b054
132
2
b082
133
2
b086
134
2
b090
135
2
b096
136
2
b099
137
2
b121
138
2
b122
139
2
b123
140
2
b124
141
2
b125
142
2
b126
143
2
H005
145
2
H205
146
2
H006
147
2
H206
148
2
H306
149
2
H050
150
2
H250
151
2
H051
152
2
H251
153
2
H052
154
2
H252
155
2
H060
156
2
H260
157
2
H070
158
2
H071
159
2
H072
160
2
C029
162
1
C041
168
2
C111
169
2
C044
170
2
C063
171
2
C061
173
2
Range
0 - 65535(*10hr)
0 - 1000.0V
0 - 1000.0V
0 - 10.00Hz
0.10 - 9.99Hz
0.1 - 99.9
0 - 100.0%
330 – 380 / 660 - 760
0 – 9999OHM
0.00 - 5.00s
0.00 - 5.00s
0.00 - 5.00s
0.00 - 5.00s
0 - 400.00Hz
0 - 200.0% (~55KW)
0 – 180.0% (75~132KW)
0.001 - 65.535
0.001 - 65.535
0 - 255
0 - 255
0 - 255
0 - 1000.0%
0 - 1000.0%
0 - 1000.0%
0 - 1000.0%
0.01 - 10.00
0.01 - 10.00
0 - 100.0
0 - 100.0
0 - 1000.0%
0 - 1000.0%
0 - 10.00
00 - 14
0 - 200.0% (~55KW)
0 – 180.0% (75~132KW)
0 - 200.0% (~55KW)
0 – 180.0% (75~132KW)
0 - 100.0%
0 - 100.00Hz
0 - 100%
Magn.
Contents
*1/10
Display time of warning
Starting voltage of Nonstop operation for
*10
Instantaneous power failure
Starting voltage of OV-LAD stop at Nonstop
*10
operation for Instantaneous power failure
Frequency width of starting deceleration
*100
at Nonstop operation for Instantaneous power
*100
Minimum frequency
*10
Coefficient of converting frequency
*10
Usage rate of BRD
*1
On level of BRD
*1
Level of Thermister error
Waiting time for establishing external braking
*100
Waiting time for acceleration at external
*100
*100
Waiting time for stop at external braking
Waiting time for confirmation signal at external
*100
*100
Release frequency of external braking
*10
Release current of external braking
*1000
1st Speed response gain
*1000
2nd Speed response gain
*1
1st Stability gain
*1
2nd Stability gain
*1
3rd Stability gain
1st Proportional gain of speed control
*10
(PI control)
2nd Proportional gain of speed control
*10
(PI control)
1st Integral gain of speed control
*10
(PI control)
2nd Integral gain of speed control
*10
(PI control)
1st Proportional gain of speed control
*100
(P control)
2nd Proportional gain of speed control
*100
(P control)
*10
1st Limiter of 0Hz control
*10
2nd Limiter of 0Hz control
*10
PI Proportion gain Change
*10
PI Integral gain Change
*100
P Proportion gain Change
code
Selection of AMI function
*10
Level1 of overload restriction warning
*10
Level2 of overload restriction warning
*10
Level over acceptable deviation of PID control
*100
Level f detecting Zero speed
*1
Warning Level of electronic thermal protection
36
failure
condition
braking
braking
Read/
Write
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/W
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/WOS
R/W
R/W
R/WOS
R/WOS
R/WOS

Advertisement

loading

This manual is also suitable for:

Sj-pbt2