ABB Relion REM615 Manual
ABB Relion REM615 Manual

ABB Relion REM615 Manual

Motor protection and control

Advertisement

Quick Links

®
Relion
615 series
Motor Protection and Control
REM615
IEC 60870-5-103 Point List Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB Relion REM615

  • Page 1 ® Relion 615 series Motor Protection and Control REM615 IEC 60870-5-103 Point List Manual...
  • Page 3 Document ID: 1MRS756882 Issued: 2010-06-11 Revision: B Product version: 3.0 © Copyright 2010 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
  • Page 5 In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.
  • Page 6 (EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive.
  • Page 7: Table Of Contents

    Table of contents Table of contents Section 1 Introduction...............3 This manual..................3 Intended audience................3 Product documentation...............4 Product documentation set............4 Document revision history.............5 Related documentation..............6 Symbols and conventions..............6 Safety indication symbols..............6 Manual conventions...............6 Functions, codes and symbols............7 Section 2 IEC 60870-5-103 data mappings........9 Overview.....................9 Point list for REM615 Ver.3.0 ME01-03..........11 Section 3 Interoperability profile for 615 series IEC...
  • Page 8 Table of contents Basic application functions............26 Miscellaneous................26 Section 4 Glossary.................27 REM615 Point List Manual...
  • Page 9: Section 1 Introduction

    Section 1 1MRS756882 B Introduction Section 1 Introduction This manual The point list manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the corresponding communication protocol manual. Intended audience This manual addresses the communication system engineer or system integrator responsible for pre-engineering and engineering for communication setup in a...
  • Page 10: Product Documentation

    Section 1 1MRS756882 B Introduction Product documentation 1.3.1 Product documentation set Engineering manual Engineering manual Engineering manual Installation manual Installation manual Installation manual Commissioning manual Commissioning manual Commissioning manual Operation manual Operation manual Operation manual Service manual Service manual Service manual Application manual Application manual Application manual...
  • Page 11: Document Revision History

    Some of the manuals are not available yet. 1.3.2 Document revision history Document revision/date Product version History A/2009-07-03 First release B/2010-06-11 Content updated to correspond to the product version Download the latest documents from the ABB web site http:// www.abb.com/substationautomation. REM615 Point List Manual...
  • Page 12: Related Documentation

    Section 1 1MRS756882 B Introduction 1.3.3 Related documentation Name of the document Document ID IEC 60870-5-103 Communication Protocol Manual 1MRS756710 Symbols and conventions 1.4.1 Safety indication symbols The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property.
  • Page 13: Functions, Codes And Symbols

    Section 1 1MRS756882 B Introduction The corresponding parameter values are "On" and "Off". • IED input/output messages and monitored data names are shown in Courier font, for example: When the function starts, the START output is set to TRUE. 1.4.3 Functions, codes and symbols Table 1: REM615 Functions, codes and symbols...
  • Page 14 Section 1 1MRS756882 B Introduction Function IEC 61850 IEC 60617 IEC-ANSI MAPGAPC1 MAP (1) MAP (1) Multi-purpose protection, instance 1 MAPGAPC2 MAP (2) MAP (2) Multi-purpose protection, instance 2 MAPGAPC3 MAP (3) MAP (3) Multi-purpose protection, instance 3 Control Circuit-breaker control CBXCBR1 I <->...
  • Page 15: Section 2 Iec 60870-5-103 Data Mappings

    Section 2 1MRS756882 B IEC 60870-5-103 data mappings Section 2 IEC 60870-5-103 data mappings Overview These tables show the default point definitions. The user is able to freely remap all these data. In that case PCM600 can provide an updated point list export of the new outlook.
  • Page 16 Section 2 1MRS756882 B IEC 60870-5-103 data mappings Frame No6 Shows if the value is present in Class2 frame 6. Frame No7 Shows if the value is present in Class2 frame 7. Comment Additional information. REM615 Point List Manual...
  • Page 17: Point List For Rem615 Ver.3.0 Me01-03

    Section 2 1MRS756882 B IEC 60870-5-103 data mappings Point list for REM615 Ver.3.0 ME01-03 REM615 Point List Manual...
  • Page 18 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 19 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 20 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 21 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 22 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 23 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 24 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 25 Section 2 1MRS756882 B IEC 60870-5-103 data mappings REM615 Point List Manual...
  • Page 27: Section 3 Interoperability Profile For 615 Series Iec 60870-5-103

    Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 Section 3 Interoperability profile for 615 series IEC 60870-5-103 Physical layer 3.1.1 Electrical interface ⊠ EIA RS-485 ⃞ Number of loads ......for one protection equipment NOTE - EIA RS-485 standard defines unit loads so that 32 of them can be operated on one line. For detailed information refer to clause 3 of EIA RS-485 standard.
  • Page 28: Application Layer

    Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 Application layer 3.3.1 Transmission mode for application data Mode 1 (least significant octet first), as defined in 4.10 of IEC 60870-5-4, is used exclusively in this companion standard. 3.3.2 COMMON ADDRESS of ASDU ⊠...
  • Page 29: Supervision Indications In Monitor Direction

    Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 ⃞ <27> Auxiliary input 1 ⃞ <28> Auxiliary input 2 ⃞ <29> Auxiliary input 3 ⃞ <30> Auxiliary input 4 Note <27>...<30>: Depending on Binary I/O options and application usage there may be additional auxiliary inputs available in the IED.
  • Page 30: Auto-Reclosure Indications In Monitor Direction

    Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 ⃞ <66> Start /pick-up L ⃞ <67> Start /pick-up N ⊠ <68> General trip ⃞ <69> Trip L ⃞ <70> Trip L ⃞ <71> Trip L ⃞ <72> Trip I>> (back-up operation) ⃞...
  • Page 31: Measurands In Monitor Direction

    Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 3.3.3.7 Measurands in monitor direction Semantics ⊠ <144> Measurand I ⊠ <145> Measurands I, V ⊠ <146> Measurands I, V, P, Q ⊠ <147> Measurands I ⊠ <148> Measurands I , P, Q, f L1,2,3 L1,2,3...
  • Page 32 Section 3 1MRS756882 B Interoperability profile for 615 series IEC 60870-5-103 3.3.5 Basic application functions ⃞ Test mode ⃞ Blocking of monitor direction ⊠ Disturbance data ⃞ Generic services ⊠ Private data 3.3.6 Miscellaneous Measurands are transmitted as Class2 data using ASDU 3 or ASDU 9. The default MVAL scalings in 615 series devices is 2.4.
  • Page 33 Section 4 1MRS756882 B Glossary Section 4 Glossary Application function block library ASDU Application-layer service data unit Circuit breaker Double point information Disturbance recorder Electromagnetic compatibility Default function type General interrogation Human-machine interface Input/output International Electrotechnical Commission IEC 60870-5-103 Communication standard for protective equipment; A serial master/slave protocol for point-to-point communication IEC 61850...
  • Page 36 Contact us ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 +358 10 22 41094 www.abb.com/substationautomation...

This manual is also suitable for:

Relion 615 seriesRelion rem615 iec

Table of Contents