Bosch Rexroth A10VO Instruction Manual page 28

Axial piston variable pump
Hide thumbs Also See for Rexroth A10VO:
Table of Contents

Advertisement

28/60
Installation
5
1)
L
L
SB
1
X
h
t min
h
S
min
1)
A10VO: For NG10 and NG28 Series 52, l
A10VNO: For NG45 and NG63 Series 52, l
2)
Only Series 53.
Fig. 8: Inside-reservoir installation A10VO with installation position 5-8
Bosch Rexroth AG, A10VO, A10VSO, A10VNO, A10VSNO Series 52 and 53, RE 92703-01-B/04.2018
Inside-reservoir installation is when the axial piston unit is installed in the reservoir
below the minimum fluid level. The axial piston unit is completely below the
hydraulic fluid.
If the minimum fluid level is equal to or below the upper edge of the pump,
see chapter 7.3.3 "Above-reservoir installation" on page 29.
Axial piston units with electric components (e.g. electric controls, sensors)
must not be installed in a reservoir below the fluid level.
Our advice is to fit a suction pipe to the suction port S and to fit a pipe to the
drain port l, l
or l
. In this case, the other drain port must be plugged. The case
1
2
of the axial piston unit must be filled before fitting the piping and filling the
reservoir with hydraulic fluid. Because complete air bleeding and filling are not
possible in installation positions 6 and 8, the axial piston unit should be air bled
and filled in a horizontal position prior to installation.
6
L
1
SB
h
t min
S
L
h
min
is opposite, l must then be connected if necessary.
1
is opposite, l must then be connected if necessary.
1
Highest drain port
l, l
, l
1
2
S
Suction port
h
Min. required immersion depth
t min
(200 mm)
Table 9: Inside-reservoir installation
Installation position
Air bleed
5 (drive shaft horizontal) via the highest available
port l
6 (drive shaft up)
via the highest available
port l
7 (drive shaft horizontal) via the highest available
port l
8 (drive shaft up)
via the highest available
port l
7
2)
L
SB
2
h
t min
S
L
h
min
h
Minimum required distance to
min
reservoir bottom (100 mm)
SB
Baffle (baffle plate)
Filling
automatically via the open port l or l
and S due to the position under the
hydraulic fuel level
automatically via the open port l, l
due to the position under the hydraulic
1
fuel level
automatically via the open port l
S by position below the hydraulic fluid
2
level
automatically via the open port l, l
due to the position under the hydraulic
fuel level
8
SB
h
t min
S
L
h
min
L
1
1
or S
1
and
2
or S
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a10vsoRexroth a10vnoRexroth a10vsno

Table of Contents