24/60
Transport and storage
After removal
Bosch Rexroth AG, A10VO, A10VSO, A10VNO, A10VSNO Series 52 and 53, RE 92703-01-B/04.2018
An uninstalled axial piston unit must be preserved with corrosion protection for the
duration of storage.
The following instructions only refer to axial piston units operated with a mineral
oil-based hydraulic fluid. Other hydraulic fluids require preservation measures
specifically designed for them. In such a case, consult your local contact person;
you can find their contact information under
www.boschrexroth.com/addresses
Bosch Rexroth recommends the following procedure:
1.
Clean the axial piston unit; see chapter 10.1 "Cleaning and care" on page 47.
2.
Drain the axial piston unit.
3.
For storage times up to 12 months: Coat the inside of the axial piston unit with
mineral oil and fill with approx. 100 ml of mineral oil.
For storage times up to 24 months: Fill the axial piston unit with VCI 329
corrosion protection (20 ml).
Fill via the drain port l, l
Fig. 13 to Fig. 17 on page 37.
4.
Seal all ports so they are airtight.
5.
Coat unpainted areas of the axial piston unit with mineral oil or suitable, easily
removable corrosion protection, e.g. acid-free grease.
6.
Package the axial piston unit with desiccant in corrosion protection film so it is
airtight.
7.
Store the axial piston unit in a shock-proof manner; see "Requirements"
on page 23 in this chapter.