<Main remote controller Menu Tree>
Initial
Main screen
* Short press for 1 Zone system.
*
F1
Information
Option
F4
F1
F2
F3
F4
Menu
Main
menu
Menu
Main
menu
Hot Water (DHW)
<See
section>
Heating/Cooling
<See
section>
Schedule timer
<See
section>
Holiday
mode
<See
section>
Initial
settings
<See
section>
<Continued to next page.>
OCH571D
Forced DHW
DHW
Heating/Cooling
Energy monitor
F1
DHW
F3
Legionella
F2
(
DHW
F4
Legionella
F1
(Zone1)
F2
(Zone2)
F3
(PREVIEW)
(
EDIT)
F4
Schedule2 period setting screen1
F4
(
EDIT)
Schedule2 period
preview screen
Schedule1/2 select
DHW
Heating/
Cooling
Holiday mode setting
F3
( EDIT)
Date/Time
Language
Summer time
Temp. display
Contact number
Time display
°C/°F
Room sensor settings
ON ( )/OFF
ON ( )/Prohibited ( )/Timer ( )
ON ( )/Prohibited ( )/Timer ( )
Consumed electrical energy
Delivered energy
Normal/Eco
Active/Non active
DHW max. temp.
EDIT)
DHW max. temp. drop
DHW max. operation time
DHW mode restriction
Hot water temp.
Frequency
(
EDIT)
Start time
Max. operation time
Duration of max. temp.
Heating room temp.(
) / Heating flow temp.(
Heating room temp.(
) / Heating flow temp.(
Compensation curve preview
F1
Zone1/2 select
Compensation curve edit
F2
F1
Zone1/2 select
Heating
F1
Zone1/2 select
Schedule1
Cooling
F4
DHW
F1
Zone1/2 select
Heating
F1
Zone1/2 select
Schedule2
Cooling
F4
DHW
Active/Non active
Active/Non active
Zone1
F1
F2
Zone1/2 select
Zone2
yyyy/mm/dd/hh:mm
EN/FR/DE/SV/ES/IT/DA/NL/FI/NO/PT/BG/PL/CZ/RU
OFF/ON
OFF/Room/Tank/Room&Tank
hh:mm/hh:mm AM/AM hh:mm
°C/°F
Room RC zone select
F1
F2
Zone1/2 select
Sensor setting
37
Long press
) / Heating compensation curve(
) / Heating compensation curve(
Curve parameters
F2
F3
Zone1
F2
Adjustment
F4
Curve parameters
F2
F3
Zone2
Adjustment
F4
F3
Term setting
F4
Schedule
F4
timer preview
Day
Zone1
select
Schedule
F4
timer preview
Day
Zone2
select
Schedule
F4
timer preview
Day
Zone1
select
Schedule
F4
timer preview
Day
Zone2
select
Schedule timer preview
Day
select
Schedule
F4
Day
timer preview
select
Zone1
Schedule
F4
timer preview
Day
Zone2
select
Schedule
F4
timer preview
Day
Zone1
select
Schedule
F4
timer preview
Day
Zone2
select
Schedule timer preview
Day
select
Heating room temp.
Heating flow temp.
Cooling flow temp.
Heating room temp.
Heating flow temp.
Cooling flow temp.
Sensor setting
Zone1
Select Time/Zone
Sensor setting
Zone2
Select Time/Zone
Unrestricted access
Installer only
Shaded items relate
to DHW functions.
These are only avail-
able if the system in-
cludes a DHW tank.
) / Cooling flow temp.
) / Cooling flow temp.
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
TH1/Main RC/
Room RC1-8/ "Time/
Zone"
Time setting
Sensor setting
TH1/RC/
Room RC1-8/ "Time/
Zone"
Time setting
Sensor setting