Dispensing / Access Control; Dispensing Menu; Access Control - Miele Profitronic M PW 6131 Programming Instructions Manual

Hide thumbs Also See for Profitronic M PW 6131:
Table of Contents

Advertisement

Dispensing / Access control

Dispensing menu

This menu is used for changing specific
dispensing data. Miele programmes are
saved to the same M.-Nr. after any
dispensing data changes. The programme
lock is not active here.
Supervisor level ~Main menu
Dispensing
Access control: Yes
^ After selecting this option the following
appears in the display:
Supervisor level ~Dispensing
1 Cottons
2 Cottons
^ After selecting a programme only its
dispensing parameters will be shown in
the display.
Dispensing ~ 1 Cottons
Area: 1 Pre-wash
Block: 1 Pre-wash
^ Select the area and block you want.
Dispensing ~ 1 Cottons
Dispensing method: No
Dispensing phase 1: X
The following options are available:
- No
- Amount in ml - Concentration ml/l
- Concentration ml/kg
If you set "Dispensing method" to: "No"
dispensing phases 1 and 2 are barred.
Dispensing ~ 1 Cottons
Dispensing phase 1: No
Dispensing phase 2: No
When setting the amount or concentration
for dispensing phases 1 and 2 you have the
choice of "No" or "User defined".
8
-
e
A
90 °C
e
60 °C
A
e
A
A
-
A
Dispensing phase 1 ~ User defined
Dispensing: 1
Dispenser pump D 1
The following options are available:
Dispensing 1 to 6
Dispenser pump: - No - D1 to D13
Dispensing phase 1 ~ User defined
Dispensing amount: 0 ml
Dispensing delay: 0 s
Dispensing amount: 0 to 9999 depending on
dispensing method - ml - ml/l - ml/kg
Dispensing delay: - No - 0 to 999 s
^ After making your selection and pressing
the S button to confirm your selection the
display will revert to the programme list and
any changes made to dispensing data will
be saved in memory. Pressing theA
button will take you back to the programme
list without saving your changes.
If any changes have been made to the
correction factor it will also need to be amended.

Access control

If access control is set to "Yes" only those
programmes which have been given free
access can be selected.
Supervisor level ~Main menu
Access control: No
Programming
The following options are available:
- No - Yes
If a programme in the programme header has
not been given free access, then the message $
"Programme locked" will appear in the display.
1
Cottons
2
Cottons
3
$ Programme locked
i
ä
e
A
-
S
A
-
e
A
90 °C
60 °C
FC
A
M.-Nr. 06 533 430