Symptom
No Water Flow
Pump won't pump
Chemical
Clogged Injection
Check Valve
Pump won't stop

TROUBLESHOOTING

Possible Cause
Closed Valve on Water Supply
Blocked Solenoid Valve
Closed or clogged discharge line
Rate Control Valve Closed
Pump is turned OFF
No Water Flow
Blocked Pump Discharge Line
Back Pressure is too high
Not enough water flow
Debris or Clumps in Polymer
Valve is stuck open allowing water into
polymer line
Water flow is still established
Pump is in internal mode
Make sure valve is open
Dis-assemble and clean valve
Remove any blockages or open any closed
valves
Make sure valve is open
Make sure pump is in ON position
Make sure all water valves (supply and
discharge) are open
Take discharge line apart, check for blockage
and clean if necessary
Reduce Back pressure on unit
Increase water flow or adjust water
monitoring device (flow switch, DP Switch,
etc.) setpoint lower than the desired flow rate
Check polymer supply for contamination
Remove valve from chamber and clean it
Shut off water valve or power to the unit
Switch pump to external