6. Graphical control
6.6.4.47 Belt control (analog output 1)
Display:
Unit:
Resolution:
Setting range:
Application:
6.6.4.48 Belt control (analog output 2)
Display:
Unit:
Resolution:
Setting range:
Application:
6-50
Analog output 1 (general applications) / upper belt (forming
machine 250) / feed belt (minced meat portioner MMP 220)
Per cent [%] / Volts [V]
1 % / 0.1 V
1 – 100 % / 0.0 - 10.0 V / -1 = Speed
External output / forming machine 250 / minced meat por-
tioner MMP 220
Enter speed.
Press Enter.
This function is used to set the speed of an external drive (e.g. feed belt).
The setting range of 0 - 100 corresponds to 0 - 10 Volt.
If you select "-1", the speed of the master and slave machines is
synchronised. The speed reflects a voltage value (e.g. 10% = 1 V)
The name for analog output 1 can be edited on the "View" page.
Analog output 2 (general applications) / lower belt (forming
machine 250) / transport belt (minced meat portioner MMP
220) / belts for kebab line)
Per cent [%] / Volts [V]
1 % / 0.1 V
1 – 100 % / 0.0 - 10.0 V / -1 = Speed
External output/kebab line and forming machine 250/
minced meat portioner MMP 220
Enter speed.
Press Enter.
This function is used to set the speed of an external drive (e.g. transport belt).
The setting range of 0 - 100 corresponds to 0 - 10 Volt.
If you select "-1", the speed of the master and slave machines is
synchronised. The speed reflects a voltage value (e.g. 10% = 1 V)
The name for analog output 2 can be edited on the "View" page.