Page 1
Navigator Series Balances Instruction Manual Balanzas serie Navigator Manual de instrucciones Balances de la série Navigator Bedienungsanleitung für die Waagen der Navigator -Serie Bilance Serie Navigator Manuale pe...
Use the instrument exclusively for weighing as described in the operating instructions. Any other type of use and operation beyond the limits of technical specifications without written consent from OHAUS, is considered as not intended. This instrument complies with current industry standards and the recognized safety regulations;...
Page 3
EN-2 Navigator 1.4 Controls Button Functions Zero Short Press (when on): Sets display to zero (when off): Turns balance on Long Press (when on): Turns the balance off Short Press (in Menu): Selects/accepts displayed setting Print Short Press: See Interface Manual for operation description. Units Long Press: Toggles through active units Short Press (in Menu): Toggles through available settings...
Navigator EN-3 2. INSTALLATION 2.1 Transportation Lock The Transportation Lock is located under the balance. Rotate the pointer to the unlocked position. 2.2 Location Use the balance on a firm, steady surface. Avoid locations with excessive air current, vibrations, heat sources, or rapid temperature changes.
EN-4 Navigator Optional rechargeable battery* Balances with the optional rechargeable battery will need to be charged for 12 hours before the balance can be operated on battery power for the first time. The battery is protected from overcharging so the balance can remain connected to the AC power. When the battery is fully charged the battery indicator on the display will stop blinking.
Navigator EN-5 3. OPERATION All modes except for weighing must be activated in the User Menu before they are available, see Section 4. 3.1 Weigh Mode 1. Press and hold Mode until [ ] (Weigh) is displayed. 2. If required, place an empty container on the pan and press Tare. 3.
EN-6 Navigator 3.4 Checkweigh Mode This mode sets low and high weight limits for portion control processes. 1. Press and hold Mode until [ ] (Check) is displayed. [ ] (clear references) will then display. 2. Press No to use the stored reference weight limits and proceed to step 5. Note: Press Function to view the low and high reference weight limits.
Navigator EN-7 4.2 Cal Sub-Menu Span [ ] (yes, no) - Initiates a span calibration procedure (zero and span). A span calibration is important when initially setting up the balance. Lin [ ] (yes, no) - Initiates a linearity calibration procedure (zero, mid-point and span). 4.3 Setup Sub-Menu Back Light [ ] (on,off,Auto)-When Back light is set to "on"...
Page 9
EN-8 Navigator 4.6 Sealing access to balance settings You can use the Menu Lock switch to limit changes to the user menu. The switch in type approved models may set some balance settings as required by the approval agency. The switch may be secured using paper seals, wire seals or plastic ties.
If the troubleshooting section does not resolve or describe your problem, contact your authorized OHAUS service agent. For service assistance or technical support in the United States call toll-free 1- 800-526-0659 between 8:00 AM and 5:00 PM EST. An OHAUS product service specialist will be available to provide assistance.
EN-10 Navigator 6. TECHNICAL DATA Equipment Ratings: Pollution degree 2; Installation category II; Altitude 2000m; Humidity: Maximum 80% for temperatures up to 31°C decreasing linearly to 50% at 40°C; non- condensing; Electrical supply: Rated 12VDC 500mA for use with a Certified/Listed power adapter or battery operated;...
EN-14 Navigator Capacity x Readability Model NV123 NV223 NV323 NV222 NV422 NV622 NV1202 Gram (g) 120 x 0.001 220 x 0.001 320 x 0.001 220 x 0.01 420 x 0.01 620 x 0.01 1200 x 0.01 Kilogram (kg) 1.2 x 0.00001 1.17679 x 2.15744 x 3.1381 x...
Page 16
Navigator EN-15 Model NVT4201 NVT6201 NVT10201 NVT2200 NVT6200 NVT12000 NVT22000 Gram (g) 4200 x 0.1 6200 x 0.1 10000 x 0.1 2200 x 1 6200 x 1 12000 x 1 22000 x 1 Kilogram (kg) 4.2 x 0.0001 6.2 x 0.0001 10 x 0.0001 2.2 x 0.001 6.2 x 0.001...
Page 17
EN-16 Navigator Approved Models Model NVT1601M NVT3200M NVT6400M NVT16000M Capacity (g) 1600 3200 6400 16000 Readability (g) Verification Interval e (g) Span Calibration Mass (Not Included) 1 kg 2 kg 5 kg 10 kg Linearity Calibration Mass 1 kg, 1.5 kg 2 kg, 3 kg 3 kg, 6 kg 10 kg, 15 kg...
Page 18
Navigator EN-17 6.2 Drawings 204 mm / 8 in. 230 mm / 9 in. 70 mm / 2.8 in. 240 mm / 9.5 in. 250 mm / 9.8 in. 74 mm / 2.9 in. NV with draft shield 204 mm / 8 in. 230 mm / 9 in.
Page 19
This product complies with the EU Directives 2011/65/EU (RoHS), 2014/30/EU (EMC), 2014/35/EU (LVD) and 2014/31/EU (NAWI). The EU Declaration of Conformity is available online at www.ohaus.com/ce. This product complies with the EU Directive 2012/19/EU (WEEE). Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment.
Navigator EN-19 Changes or modifications not expressly approved by the party responsible for compliance could void Industry Canada Note This Class B digital apparatus complies with Canadian ICES-003. ISO 9001 Registration The management system governing the production of this product is ISO 9001 certified.
Need help?
Do you have a question about the Navigator NV123 and is the answer not in the manual?
Questions and answers