CASIO STANDARD W219 - 10 Bar WR Watch Manual
![]()
About This Manual
- Depending on the model of your watch, display text appears either as dark figures on a light background, or light figures on a dark background. All sample displays in this manual are shown using dark figures on a light background.
- Button operations are indicated using the letters shown in the illustration.
![]()
- Each section of this manual provides you with the information you need to perform operations in each mode.
- Note that the product illustrations in this manual are intended for reference only, and so the actual product may appear somewhat different than depicted by an illustration.
General Guide
- Press
to change from mode to mode. - After you perform an operation in any mode, pressing
returns to the Timekeeping Mode. - The watch returns to the Timekeeping Mode automatically if you do not perform any button operation for one or two minutes in the Alarm Mode and Time Setting Mode.
- In any mode, press
to illuminate the display.
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - General Guide - Changing modes General Guide - Changing modes]()
Timekeeping
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Timekeeping - Interface description Timekeeping - Interface description]()
Use the Timekeeping Mode to view the current time and date.
- Day of the week is displayed as follows.
SU: | Sunday | MO: | Monday |
TU: | Tuesday | WE: | Wednesday |
TH: | Thursday | FR: | Friday |
SA: | Saturday | | |
To toggle between 12-hour and 24-hour timekeeping
In the Timekeeping Mode, press
to switch between the 12-hour and 24-hour formats.
- With the 12-hour format, the PM indicator appears for times in the range of noon to 11:59 p.m. and no indicator appears for times in the range of midnight to 11:59 a.m.
- With the 24-hour format, times are displayed in the range of 0:00 to 23:59, with 24H indicator.
Alarm
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Alarm - Interface description Alarm - Interface description]()
When the Daily Alarm is turned on, the alarm sounds for 20 seconds at the preset time each day. When the Hourly Time Signal is turned on, the watch beeps every hour on the hour.
- All of the operations in this section are performed in the Alarm Mode, which you enter by pressing
.
To set the alarm time
- In the Alarm Mode, press
. The hour digits flash because they are selected.
- This operation automatically turns on the alarm.
- Press
to change the selection in the following sequence.
![]()
- Press
to increase the selected digits. Holding down A changes the number at high speed.
- The format (12-hour and 24-hour) of the alarm time matches the format you select for normal timekeeping.
- When setting the alarm time using the 12-hour format, take care to set the time correctly as morning or afternoon (PM).
- After you set the alarm time, use
to return to the Alarm Mode.
- If you do not operate any button for one or two minutes while a selection is flashing, the flashing stops and the watch goes back to the Timekeeping Mode automatically.
To stop the alarm
Press any button to stop the alarm after it starts to sound.
To switch the Daily Alarm the Hourly Time Signal on and off
Press
while in the Alarm Mode to change the status of the Daily Alarm and Hourly Time Signal in the following sequence.
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Changing the status of the Alarm Changing the status of the Alarm]()
To test the alarm
Hold down
while in the Alarm Mode to sound the alarm.
Stopwatch
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Stopwatch - Interface description Stopwatch - Interface description]()
The Stopwatch Mode lets you measure elapsed time, split times, and two finishes. The range of the stopwatch is 59 minutes, 59.99 seconds.
- The stopwatch continues to run, restarting from zero after it reaches its limit, until you stop it.
- The stopwatch measurement operation continues even if you exit the Stopwatch Mode.
- Exiting the Stopwatch Mode while a split time is frozen on the display clears the split time and returns to elapsed time measurement.
- All of the operations in this section are performed in the Stopwatch Mode, which you enter by pressing
.
To measure times with the stopwatch
- Elapsed time measurement
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - To measure times with the stopwatch - Elapsed time To measure times with the stopwatch - Elapsed time]()
- Split time measurement
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - To measure times with the stopwatch - Split time To measure times with the stopwatch - Split time]()
- Split time and 1st-2nd place times
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Stopwatch - Measuring split & 1st/2nd place times Stopwatch - Measuring split & 1st/2nd place times]()
Time Setting
![CASIO - STANDARD W219 - 50-Meter WR Watch Manual - Time Setting - Interface description Time Setting - Interface description]()
Use the Time Setting Mode to set the current time and date.
To set the time and date
- Use
to enter the Time Setting Mode.
- The second's digits flash because they are selected.
- Press
to change the selection in the following sequence.
![]()
- While the second's digits are selected (flashing), press
to reset the seconds to
. If you press
while the second's count is in the range of 30 to 59, the seconds are reset to
and 1 is added to the minutes. If the second's count is in the range of 00 to 29, the minute's count is unchanged. - While any other digits (besides seconds) are selected (flashing), press
to increase the number. While the day of the week is selected, pressing
advances to the next day. Holding down
changes the current selection at high speed. - After you set the time and date, press
to return to the Timekeeping Mode.
- If you do not operate any button for one or two minutes while a selection is flashing, the flashing stops and the watch goes back to the Timekeeping Mode automatically.
Specifications
Accuracy at normal temperature: ±30 seconds a month
Timekeeping: Hour, minutes, seconds, p.m., day, and day of the week
Time system: Switchable between 12-hour and 24-hour formats
Calendar system: Auto-calendar set at 28 days for February
Alarm: Daily alarm, Hourly time signal
Stopwatch
Measuring units: 1/100 seconds
Measuring capacity: 59 minutes, 59.99 seconds
Measuring modes: Elapsed time, split time, and two finishes
Illumination: LED (light-emitting diode)
Battery: One lithium battery
Type: CR2016
Battery life: Approx. 7 years
- 1 second of illumination operation per day
- 20 seconds of alarm operation per day
![]()
Documents / ResourcesDownload manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download CASIO STANDARD W219 - 10 Bar WR Watch Manual
Need help?
Do you have a question about the STANDARD W219 - 50-Meter WR Watch Manual and is the answer not in the manual?
Questions and answers