CAME RIO-CONTROL - Controller Manual

CAME RIO-CONTROL - Controller Manual

Advertisement

CAME RIO-CONTROL - Controller Manual

Description

Description

Device for managing up to 10 RIO-series accessories via radio. Figure A shows nine units interfaced with RIO-CONTROL.
Nine units interfaced with RIO-CONTROL

Main control-card components

Main control-card components

  1. Antenna.
  2. Buzzer.
  3. Radio power-range selector switch.
  4. Warning LED.
  5. Programming button.
  6. Reset button.
  7. Flashing light input.
  8. Terminals for connecting to the control panel, - see figure :
    Terminals for connecting to the control panel

Technical data

Type RIO-CONTROL
Power supply (V) 24 AC/DC
Maximum draw (mA) 80
Relay contacts 24 V max. (A) 1
Radio range over clear areas (m) 30 max.
Frequency (MHz) 868.95 - 869.85

Installation

warning Before continuing, cut off the MAINS POWER SUPPLY and disconnect any batteries.

Fitting the casing and control card

Fitting the casing and control card

  • Drill the pre-punched holes needed for passing through the cables .
  • Fasten the casing, using dowels and/or screws suitable for the surface.
  • Fit the card and slide it along the corresponding rail guide.
    NB: Do not change the antenna's position.
  • After connecting the cables (see example in figure ), power up the system and check that the blue wireless LEDs are flashing. If they are not flashing, reset the card (see corresponding procedure).
  • Remove batteries from the accessories.
  • Memorize each single component of the system (see accessories instructions).
  • Test system's functionality (see corresponding procedure) and close the cover by fastening it to the base using the supplied screw .

Description of terminal board

(See Fig. )

10-2 Power supply input 24 V AC/DC
10-E Flashing light input 24 V AC/DC
TS Safety-test input (if unused, bridge with 2)
IN1 - IN2 Not used
OUT1 (NC) Output activated by input IN1 of RIO EDGE memorized on T1.
OUT2 (NC) Output activated by input IN2 of RIO EDGE memorized on T2.
OUT3 (NC) Output activated by RIO CELL memorized on T1.
OUT4 (NC) Output activated by RIO CELL memorized on T2.
OUT5 (NC) Not used
LAMP-230 V Flashing light input at 230 V

warning You cannot simultaneously connect the flashing lights to the 24 V AC/DC and 230 V AC inputs .

Connection to the control panels.

(See Fig. )

warning Always connect the LAMP terminal to the W-E1 terminals on the 230 V panels or the RIO-CONTROL 10-E input to the 10-E or 10-E1 terminals of the 24 V panels .

  • Always enable the pre-flashing.
  • Enable the services test (if present).
  • Generally avoid those conditions in which when the operator is idle the flashing light is active.

For example, with function C4 enabled on the CAME panel, if the photocell is engaged, the RIO accessories shall remain active for the entire intervention period, thus reducing battery life.

Card resetting

Keep the RESET button pressed for about 10 seconds, the wireless LEDs flash.

NB: Replacing a device means that you will have to reset the card and again memorize all the devices on the system.

Functional checks

Press a command button (each Rio accessory flashes* blue) Check that RIO-LUX activates.
Obstruct the gate's action and check whether the RIO-CELL and/or
FA00107M4A - ver. 1 - 05/2015

RIO-EDGE devices actually activate prescribed safety function. When the maneuver ends, each Rio accessory will flash* red and then go into Low Power mode to preserve the batteries.

warning NB: In Low-Power mode, the manual test response time (that is, the flashing blue LED), will be slower.
* If this does not happen, cut off the mains power supply and increase the radio signal's range/power by setting the jumper
to position H.

Troubleshooting

LED permanently glowing,
LED switched off,
LED flashes
Buzzer ON, Buzzer OFF

Warnings Possible causes Fix
WIRELESS
TS terminal (safety devices test) not wired. Connect the TS terminal to the corresponding one on the panel. If the corresponding one is lacking on the panel, connect it to terminal 2.
WIRELESS
No Rio accessory is memorized. Configure RIO accessories.
WIRELESS
The sensitive edge connected to IN1 of RIO-EDGE fails to intervene. Check settings and adjustments on the sensitive safety-edge.
WIRELESS
The sensitive safety-edge connected to IN2 on RIO-EDGE fails to intervene. Check settings and adjustments on the sensitive safety-edge.
WIRELESS
The Rio-Cells memorized with T1:
  1. Detect an obstruction.
  2. Are misaligned.
  3. Have flat batteries.
  1. Remove the obstruction.
  2. Align the photocells.
  3. Replace the batteries.
WIRELESS
The Rio-Cells memorized with T2:
  1. Detect an obstruction.
  2. Are misaligned.
  3. Have flat batteries.
  1. Remove the obstruction.
  2. Align the photocells.
  3. Replace the batteries.
WIRELESS
RIO-EDGE or RIO-CELL is not communicating with RIO-CONTROL.

Check the radio-transmission efficiency.

Make sure the batteries are charged.

Pertinent Regulations. RIO-CONTROL paired with RIO-EDGE together with an operator (or control panel) with safety test enabled, is a category 2 safety device (EN 954-1).

warning Modifying the project or set up of the device without first checking with the manufacturer or authorized dealer may be hazardous.

Once installed, check compliance with the applicable parts of the following regulations: EN 13241-1, EN 12453, EN 12445.
Came S.p. A. is not liable for any damage caused if the product is used improperly, wrongfully or unreasonably.

Declaration . Came S.p. A. hereby declares that this device complies with the essential requirements and other pertinent provisions established in regulation 2006/95/CE, 199/5/CE. An original copy is available on request.

Decommissioning and disposal. - Do not dispose of the packaging and the device, at the end of its life cycle, in nature, but rather dispose of them by following the applicable laws in the country where the device is installed. The recyclable components all bear a symbol to that effect.

THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE.
THE MEASUREMENTS, UNLESS OTHERWISE STATED, ARE IN MILLIMETERS.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download CAME RIO-CONTROL - Controller Manual

Advertisement

Need help?

Need help?

Do you have a question about the RIO-CONTROL and is the answer not in the manual?

Questions and answers

Table of Contents