Primary Filters; Compressor; Water Separator - Husqvarna DC 655 Operator's Manual

Hide thumbs Also See for DC 655:
Table of Contents

Advertisement

Available languages

Available languages

primary filters. The pressure is around 7 bar/100 PSI
during operation.

Water separator

The water separator removes dirt, oil and water from the
air.
To connect a secondary product
1. Connect the power plug of the secondary product to
an applicable power supply or to the product.
2. Make sure that the dust extraction hose between the
product and the secondary product is connected with
hose clamps and industrial tape.
3. Make sure that the dust extraction hose is in good
condition and can move freely.
To connect the product to a power
source
1. Connect the power plug of the product to a grounded
mains outlet or other power source.
2. Make sure that the mains voltage agrees with the
type plate on the product.
To start the product
1. Connect the dust extraction hose between the
product and the secondary product.
2. Connect the product to a power supply.
2061 - 001 - 13.02.2023
3. Set the ON/OFF switch to the ON position.
4. Start the compressor.
5. Start the fan.
To set the correct phase
If the indicator for the incorrect phase is on, there is a
phase error, and it is necessary to change the position
of the phase converter switch.
1. Disconnect the product from the power source.
2. Open the control panel.