Disarming Under Duress; Partition Selection Process; Switching From 'Home' To 'Away; Switching From 'Away' To 'Home - Visonic PM-10 TRIPLE User Manual

Table of Contents

Advertisement

PRESS
[Enter Code] /
[Present tag]
ARM indicator extinguishes during the disarmed state. Disarming the system also stops the siren alarm,
irrespective of whether the alarm was initiated during the armed or the disarmed state.

Disarming under Duress

If you are forcibly compelled to disarm the system, enter the duress code (2580 by default) or another code set
by the installer. Disarming will take place normally but a silent alarm will be transmitted to the monitoring station.

Partition Selection Process

Access to any desired partition is achieved through the use of an individual code or proximity tag. It is not
possible to access the INSTALLER MENU if one or more partitions are in the AWAY or HOME modes.
Before attempting to perform any operation on any given partition(s), it is necessary to perform the operations
below which enable you to select the desired/allowed partition(s) using the individual code or proximity tag:
PRESS
Enter partition # (1 - 3)
Note: The "Failure Tune" will be heard when selecting a partition to which no sensors / peripherals were
enrolled.
Special Arming & Disarming Options
In addition to basic arming, PowerMaster provides you with several advanced arming and disarming options:

Switching from 'HOME' to 'AWAY'

You do not have to disarm the system - just press
AWAY above. Vacate the premises before the exit delay expires.

Switching from 'AWAY' to 'HOME'

You do not have to disarm the system - just press
Master will ask you to key in your master user code or user code, thus making sure that you are an authorized user.
PRESS
[Enter code] /
[Present tag]
Move to interior zone
ARM indicator flashes during the armed state.

Arming AWAY or HOME 'Instant'

Pressing
during the exit delay will arm the system in the "Instant' mode, i.e. without an entry delay.
Therefore, any detection in any zone will trigger an immediate alarm. To arm AWAY-INSTANT, proceed as follows.
D-307502 PowerMaster-10/30 G2 User's Guide
OPERATING THE POWERMASTER SYSTEM
RESULTING DISPLAY
PRESENT TAG OR
ENTER CODE
_ _ _ _
Code / Present gag
READY
HH:MM
RESULTING DISPLAY
SELECT PARTITION
PARTITION 1
RESULTING DISPLAY
PRESENT TAG OR
ENTER CODE
_ _ _ _
Code / Present tag
ARMING HOME
 (Exit delay) 
ARM HOME HH:MM
. The response will be the same as in ARMING
. Since this operation reduces the security level, Power-
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM-10 TRIPLE and is the answer not in the manual?

Questions and answers

kate and jon mcgregor
January 19, 2025

the orange light will not go off even though system working ok

1 comments:
Mr. Anderson
February 4, 2025

The orange light on the Visonic PM-10 TRIPLE indicates a trouble condition. To resolve this, review the trouble messages displayed on the panel. Possible issues could include a low battery in a device, an inactive device, or a failed communication attempt. Follow the steps to identify and correct the specific trouble source:

1. Press the button repeatedly to view each trouble message.
2. Address the indicated issues, such as replacing low batteries or reactivating inactive devices.

Once all troubles are resolved, the orange light should turn off.

This answer is automatically generated

This manual is also suitable for:

Powermaster-30 g2Powermaster-10 g2