PowerMaster-10/30 G2 Installer's Guide
Refer to the following changes that replace the equivalent information in the supplied installer guide.
5.4.2 Adding New Wireless Devices or Wired Sensors
Part B – Configuration
Zone Type List
No.
Zone Type
Description
25
Custom 1
A custom zone type that reports to private phone, and SMS numbers without activating any
sirens. This setting is configured to perimeter by default. To define the setting default, refer to
section 5.8.4 Custom Zone Types.
26
Custom 2
A custom zone type that reports to private phone, and SMS numbers without activating any
sirens. This setting is configured to perimeter by default. To define the setting default, refer to
section 5.8.4 Custom Zone Types.
5.4.7 Defining Configuration Defaults for "Device Settings"
The default configuration of the 'VIEW ON DEMAND' feature is 'disabled'. To change the default configuration,
complete the following steps:
Changing VIEW ON DEMAND defaults
[1]
Enter the installer menu and select 02:ZONES/DEVICES
[2]
Select DEFINE DEFAULTS
[3]
Select MOTION SENSORS
[4]
Select VIEW ON DEMAND and choose the desired default setting from the list of options
Note: The selected default setting is marked with
Note: The new default affects only new motion cameras enrolled after the change is performed.
5.5.5 Configuring Sirens Functionality
In previous versions, an alarm that occurred in a single partition activated all sirens in the system. From PowerMaster
v20.2 onwards, you can configure the system so that the siren sounds only when an alarm is triggered within the same
partition.
Option
Configuration Instructions
48:SRN PER PRTN
5.5.6 Configuring Audible & Visual User Interface
Option
Configuration Instructions
56:SCREEN SAVER
With partition disabled
D-307494 PowerMaster-10/30 G2 Installer Guide Addendum
V20.2 UPDATES
This setting determines if the siren activates when an alarm occurs within the same partition.
Note: This option does not apply to sirens that are embedded in the panel or wired sirens that
are connected to expanders or PGMs.
If you set the siren to Enable, and an alarm is triggered in the same partition, the siren sound
and the exit and entry beeps activate.
Note: To silence a siren within a partition, you must have access privileges to that partition.
If set to Disable, the siren sound, as well as exit and entry beeps, are activated when an alarm
is triggered in any partition.
If you set the siren to Disable, and an alarm is triggered in any partition, the siren sound and
the exit and entry beeps activate.
Options: Disable (default) or Enable.
The screen saver option - when activated - replaces the status display on the control panel
with the words "SECURITY SYSTEM" if no key is pressed for more than 30 seconds.