Samsung MIM-E03CN Installation Manual page 32

Air to water heat pump
Hide thumbs Also See for MIM-E03CN:
Table of Contents

Advertisement

DHW tank
Booster heater
Booster heater
Recommended wire specification
Load
Use Booster Heater (Max. 3kW)
❈ Code designation IEC: 60245 IEC 57/ CENELEC: H05RN-F
Connecting a booster heater (PTC heater – allowed limit : Max. 3kW)
1. Directly connect a 'Booster heater' with 'A3 and A4 ' in TB-A.
• Wire spec : 6.0 mm
• Code designation IEC : 60245 IEC 57 / CENELEC : H05RN-F
NOTE
Specification table
Terminal Block (output)
Connection load
Output (N, L)
32
Power Supply
1Ø, 220-240V, 50Hz
2
(regardless of distance)
Part
Power Cable
mm
2
, wires
4.0 / 3
6.0 / 3
Specification
N, L of TB-A1
Direct connection a booster heater
AC 230V (MAX 20A)
Max. Length
m
L < 10m
10m < L

Advertisement