DIAG:RESUlt?
Group
Related Commands
Syntax
Arguments
Returns
Examples
DIAG:SELect (?)
Group
Related Commands
VX4792 User Manual
The DIAG:RESUlt? query returns results of self-test execution.
CALIBRATION and DIAGNOSTIC
DIAG:SELect, DIAG:STATe
DIAG:RESUlt?
DIAG
:
None
:DIAG:RESULT<Result>[,<Result>]...<Result>::=<NR1>
where <NR1> is one of following values:
0
terminated without error
100
detected an error in the CPU unit
600
detected an error in the setup-related unit
700
detected an error in the waveform memory unit
:DIAG:RESULT?
might return :DIAG:RESULT 100
The DIAG:SELect command selects the self-test routine. The DIAG:SELect?
query returns currently selected routine. The DIAG:STATe command executes the
routine.
CALIBRATION and DIAGNOSTIC
DIAG:STATe, DIAG:RESULt?
RESUlt
?