About this Document 3/54 About this Document The present manual applies to the E450 ZCX110Px and E450 ZCX120Px Range of validity PLC 1-phase electricity meters. For a detailed explanation of the type designation see section 1.4. Purpose The user manual contains all information required for meter applications for the intended purpose.
General View Fig. 1.1 General view of meter Functional Overview E450 is a smart electricity meter offering reliable performance with versatile functionality including support for multi energy reading and control. Two- way communication using Power Line Carrier (PLC) technology enables integration to AMM systems and multi-energy support extends the reading and control possibilities even further.
8/54 Description of Unit Type Designation The exact configuration of E450 meters is expressed in a type code printed on the device faceplate. The type code can also be read by the metering system. Example Network type 3-phase, 4-wire (M-connected)
Relay output 2 (terminals 25 and 26) is an 8 A mechanical normal open relay. Both relay outputs of the E450 meters can be operated in normal mode or inverted mode. The inversion can be controlled either remotely or via the user interface.
Disconnector The E450 meter is equipped with a disconnector to connect or disconnect the premises of the consumer. The disconnector can be operated manually via push button, remotely by commands via any communication channel, via input or locally through control functions integrated in the meter itself.
In particular, the owner of the meters bears responsibility for the protection of persons, prevention of material damage and the training of personnel. For this purpose, Landis+Gyr provides training on a variety of products and solutions. Please contact your local Landis+Gyr representative if interested.
The installation site must meet the requirements of the device’s protect- tion class (IP53) and the operating temperature range (-40 … +70°C). The E450 is intended for indoor use, but outdoor installation is possible with external housing and warming/cooling (then other temperatures are possible).
OBIS Codes of Displayed Values The following table shows a list of commonly used display items and their OBIS codes. The display list of the E450 meter is programmable and therefore additional codes may appear. Please refer to the E450 functional description for further details.
Operation 45/54 Disconnector Control The E450 meter has an integrated disconnector to connect or disconnect power to the customer premises. The disconnector can be controlled: • Manually, with an integrated push button or via a pulse input where an external push button is wired •...