Settings
Baudrate
50
100
200
600
1200
2400
Table 14:
Possible configuration of frequency deviation per baudrate
Additionally, with the command
< s e t i n t e r f a c e f s k 0 { r x | t x } f r e q u e n c y F
all center frequencies can be configured that fulfill the requirements:
F
+ ΔF ≤ 3240 Hz
C
F
- ΔF ≥ 390 Hz.
C
The possible values for F
420,
450,
840,
870,
1260, 1320, 1350, 1380, 1410, 1440, 1500, 1530, 1560, 1590, 1620, 1680,
1700, 1710, 1740, 1770, 1800, 1860, 1890, 1920, 1950, 1980, 2000, 2040,
2070, 2100, 2130, 2160, 2220, 2250, 2310, 2340, 2400, 2430, 2460, 2490,
2520, 2580, 2610, 2640, 2670, 2700, 2760, 2790, 2800, 2820, 2850, 2880,
2940, 2970, 3000, 3030, 3060, 3120, 3150, 3180, 3210.
2.9.3

Transmission level

The transmission level is set
• in accordance with the chosen bit rate or
• can be set as a function of the allocated transmission channels.
In addition the transmission level can be doubled at the output stage.
Commands to set the transmission level
< s e t i n t e r f a c e f s k 0 t x l e v e l b a u d r a t e >
< s e t i n t e r f a c e f s k 0 t x l e v e l { - 6 | - 9 | - 1 2 | - 1 3 . 8 | - 1 5 . 6
| - 1 7 . 2 | - 1 8 . 6 | - 1 9 . 8 | - 2 1 . 1 } >
< s e t i n t e r f a c e f s k 0 t x [ n o ] i n c r e a s e - l e v e l >
Baudrate
50
100
200
600
1200
2400
Table 15:
Baudrate dependent transmit level
22
are the following:
C
480,
510,
540,
600,
900,
960,
990, 1020, 1050, 1080,
Frequency deviation ΔF
25, 30
45, 60
90, 120
190, 200, 210, 240
300, 400
400, 800
>
C
630,
660,
690,
1140,
1170, 1200, 1230,
Transmit Level
-22.5 dBm
-19.5 dBm
-16.5 dBm
-12.0 dBm
-8.7 dBm
-6.0 dBm
Functions
720,
780,
810,
1KGT151043 V001 1