Default Configuration And Reset Of A Device - Hitachi EDS500 Series Manual

Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Loading and saving a configuration
"Tab. 2: Modification of configuration with and without plugged-in configuration stick" shows which
configuration is modified by which action.
Action
1. Delivery State
2. Power on (no configuration stick)
3. Command input <set ...>
4. Command input <copy running-con-
fig startup-config>
5. Command input <set ...>
6. Plug in configuration stick
7. Command input <copy running-con-
fig stick-config>
8. Command input <set ...>
9. Device restart (with configuration
stick)
Table 2:
Modification of configuration with and without plugged-in configuration stick
2.4.4

Default configuration and reset of a device

The default configuration of a device contains configuration commands that allow access to the
broadest set of functions of a system. On shipping all devices have the default configuration. The
default configuration is not identical with an empty configuration.
Device Settings
Host name
Baud rate Con0
Baud rate DTE
Center frequency
Deviation
Transmit level
Receiver amplification
2/4-Wire
Table 3:
Parameters of the default configuration
To reset a device to the default values automatically, the following options are available:
– Via command <reload -default-config>
– At the serial interface console0 during startup and pressing the key i(gnore) once.
Instead of the start up configuration the default configuration is loaded. The device internal startup
configuration remains unchanged. For security reasons the start up configuration cannot be
accessed after booting with the default configuration.
If the device should use the default values permanently then the default configuration has to be
saved with the command <write>.
14
Current device
configuration
(running-config)
-
A1
A2
A2
A3
A3
A3
A4
A3
Value
modem
57600 bps, 8N1
2400 bps, transparent
2000 Hz
400 Hz
-6 dBm
6 dB
2-Wire
Internal startup
configuration
(startup-config)
A1
A1
A1
A2
A2
A2
A2
A2
A3
Implicit default value
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Functions
Configuration
stick (stick-con-
fig)
-
-
-
-
-
B1
A3
A3
A3
Explicit command
No
No
No
No
No
No
No
No
1KGT151043 V001 1