Factory Setting - Pepperl+Fuchs UC2000-30GM-2EP-IO-V15 Manual

Ultrasonic sensor, single head system
Table of Contents

Advertisement

Ultrasonic sensor
Note
The last beam width programmed applies for both outputs in equal measure.

Factory Setting

Resetting the sensor to the factory settings
The sensor can be reset to the original factory settings.
1. Disconnect the sensor from the power supply
2. Press and hold one of the push buttons
3. Connect the power supply (yellow and red LEDs flash simultaneously for 5 seconds, followed by the yellow and green LEDs flashing
simultaneously)
4. Release the push button
The sensor will now function with the original factory settings.
Factory settings
See technical data.
Indication
Indicators
The sensor has four LEDs for indicating the status and two buttons for setting parameters.
In normal mode
Error-free operation
Fault (e.g. compressed air)
When programming the switching points or
trip values
Object detected
No object detected
Confirmation, programming successful
Warning, programming invalid
When programming the operating mode
Programming the output mode
Programming the output behavior
Programming the sound cone
Commissioning
Synchronization
The sensor is fitted with a synchronization input that suppresses mutual interference from external ultrasonic signals. If this input is not connected,
the sensor operates with internally generated cycle pulses. The sensor can be synchronized by creating external rectangular pulses and by
setting the appropriate parameters via the IO-link interface. Each falling pulse edge sends an individual ultrasonic pulse. If the signal at the
synchronization input is low for >1 second, the sensor reverts to the normal, unsynchronized operating mode. This also occurs if the
synchronization input is disconnected from external signals (see note below).
If a high signal is applied to the synchronization input for > 1 second, the sensor switches to standby. This is indicated by the green LED. In this
operating mode, the last recorded output statuses are retained. Please observe the software description in the event of external synchronization.
Note:
If the option of synchronizing is not used, the synchronization input must be connected to ground (L-) or the sensor must be operated with a V1-
connection cable (4-pin).
The option of synchronization is not available during the programming process. During synchronization, the sensor can switch to programming
via the IO-link interface. This interrupts the synchronization process and the sensor is no longer synchronized.
The following synchronization modes are available:
1. Multiple sensors (see Technical data for the maximum number) can be synchronized by connecting the synchronization inputs on the sensors.
In this case, the sensors synchronize themselves in succession in multiplex mode. Only one sensor sends signals at any one time. (See note
below)
2. Multiple sensors (see Technical data for the maximum number) can be synchronized by connecting the synchronization inputs on the sensors.
The sensor interface can be used to parameterize the sensors so that one functions as a master and the others function as slaves. (See
interface description) In this case, the sensors in master/slave mode work simultaneously, i.e. in synchronization where the master sensor
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
USA: +1 330 486 0001
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
LED, green
LED L1, yellow
On
The output status
Off
retains the last
status
Off
Flashes
Off
Off
Flashes 3x
Off
Off
Off
Flashes
Off
Off
Flashes
Off
Off
L1
LED yellow
T1
T2
L2
LED
green/red
Germany: +49 621 776 1111
fa-info@de.pepperl-fuchs.com
LED L2, yellow
LED, red
The output status
Off
retains the last
On
status
Flashes
Off
Off
Flashes
Off
Off
Off
Flashes 3x
Off
Off
Flashes
Off
Off
Flashes
L1
LED yellow
L2
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
UC2000-30GM-2EP-IO-V15
7