Upgrade Has Been Terminated; The Date And Time Is Not Adjusted Automatically By The Ntp Server - Sanyo VCC-HD2500P Manual

Hide thumbs Also See for VCC-HD2500P:
Table of Contents

Advertisement

Upgrade has been terminated.

Upgrade has been interrupted due to power off, network fault, or other problem during the process.
Redo the upgrade by proceeding as follows.
1
Turn on the camera again.
2
Access the camera again.
3
Check the firmware version on [FIRMWARE UPDATE] in OPTION SETTINGS screen.
* If the version number is updated: Upgrade is complete.
* If the version number is not updated: Redo the upgrade.

The date and time is not adjusted automatically by the NTP server.

1
The GATEWAY settings are not configured correctly.
Select NETWORK and configure the [GATEWAY] settings again.
2
The NTP server address is not configured correctly.
Select CLOCK and configure the [NTP SERVER ADDRESS] settings again.
3
Adjustment by NTP is not set as the method for automatic time adjustment.
Select CLOCK and set [CLOCK ADJUST] to [ON (NTP)].
The date and time information indicated on the live screen does not reflect the clock settings
configured on the [CLOCK SETTINGS] screen.
It is recommended that you delete temporary Internet files.
To do so, in Internet Explorer, click [Internet Options] in the [Tools] menu and then delete
temporary files, history, cookies, saved passwords, and web form information from the [General]
tab.