Part Name
Gas Valve
(25M01A)
6
7
Igniter (101D)
Gas
Thermostat
(60T21 Hi-Limit)
230F-50F
Image
4
1
2
3
120V, 60Hz, 120A
120V, 4.5A
250V, 25A (60T2)
Valve 1-2: Resistance value approx. 1365Ω
Valve 1-3: Resistance value approx. 560Ω
Valve 4-5: Resistance value approx. 1325Ω
Valve 6-7: Resistance value approx. 1000Ω
5
If resistance is infinite, replace valve.
Resistance value 40~400Ω
If resistance is infinite, replace igniter.
Resistance value < 1Ω
If resistance is infinite, replace thermostat.