ABB Tina 2A Original Instructions Manual

ABB Tina 2A Original Instructions Manual

Adaptor unit
Hide thumbs Also See for Tina 2A:

Advertisement

Quick Links

Original instructions
Tina 2A/B
Adaptor unit
ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden
www.jokabsafety.com

Advertisement

Table of Contents
loading

Summary of Contents for ABB Tina 2A

  • Page 1 Original instructions Tina 2A/B Adaptor unit ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com...
  • Page 2 DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
  • Page 3: Table Of Contents

    Table of Contents Introduction ............................4 Scope ................................4 Audience ................................4 Prerequisites ..............................4 Special notes ..............................4 Overview .............................. 5 General description ............................5 Safety regulations .............................. 5 Connections ............................6 Connection examples............................7 Installation and maintenance ......................8 Installation precautions ............................
  • Page 4: Introduction

    Introduction Scope The purpose of these instructions is to describe the adaptor units Tina 2A/B and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB/Jokab Safety products.
  • Page 5: Overview

    Vital safety module or Pluto safety-PLC. Tina 2A and Tina 2B are used to adapt safety sensors with mechanical contacts to the dynamic safety circuit. Examples of such safety sensors are emergency stops and switches or light curtains and light beams with internal relay outputs.
  • Page 6: Connections

    Connections 5-pole connection cables: 1 ) Brown: +24 VDC 2 ) White: Dynamic signal input 3 ) Blue: 0 VDC 4 ) Black: Dynamic signal output 5 ) Grey: Information NB: The connection cable cross section area is 0.34 mm and cable length is 150 mm.
  • Page 7: Connection Examples

    Connection examples Caution! All cable colours according to ABB/Jokab Safety standard cables. More connection examples can be found at www.jokabsafety.com or in the Safety Handbook. 2TLC172119M0201, rev. A www.jokabsafety.com 2011-09-20...
  • Page 8: Installation And Maintenance

    Installation and maintenance Installation precautions The unit must first attach to the M20 connector (Tina 2A) before the safety loops are connected to the sensor. Warning! All the safety functions must be tested before starting up the system. Maintenance Warning! The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly (EN 62061:2005).
  • Page 9: Operation

    Operation LED indication Indication Description Input signal on pin-2 Green Safety circuit closed (protection OK) Dynamic signal in LED on Tina Green-Red (flash) Safety circuit open (protection OK) No dynamic signal in or 0 VDC in +24 VDC in Information output signal attributes The information output of the unit (pin-5) is set either high (+24 VDC) or low (0 VDC) depending on four different input signals (pin-2): Dynamic signal - Dynamic signal input exist, i.e.
  • Page 10: Technical Data

    Housing material Connector 5x 0.34 mm wires, 0.15 m Size Tina 2A: 46 x 27 x 24 mm Tina 2B: 26 x 21 x 7 mm (L x W x H) Weight Tina 2A: ~30 g Tina 2B: ~20 g...
  • Page 11: Dimensions

    Dimensions Tina 2A Tina 2B NB: All measurements in millimetres. 2TLC172119M0201, rev. A www.jokabsafety.com 2011-09-20...
  • Page 12: Ec Declaration Of Conformity

    EC Declaration of conformity EC Declaration of conformity (according to 2006/42/EC, Annex2A) ABB AB declare that the safety components of ABB AB make with type designations and safety JOKAB SAFETY functions as listed below, is in conformity with the Directives Varlabergsvägen 11...

This manual is also suitable for:

Tina 2ab

Table of Contents