Zyxel WAC6552D-S - 802.11 Ac Unified Pro Outdoor Access Point Quick Start Guide
![]()
Hardware Installation
![Zyxel - WAC6552D-S - Hardware Installation Hardware Installation]()
- Connect the UPLINK port to an AP Controller (AC), router or computer through a PoE injector (30W, lightning protection 6kV).
- Connect the CONSOLE port to your computer using a RJ-45-to-DB9 console cable (not included) for troubleshooting.
Managed AP Mode (Option 1)
-
- When the WAC6552D-S and a Zyxel AP controller (NXC2500 for example) are in the same network, the WAC6552D-S will automatically be managed and configured by the controller. To set up the WAC6552D-S, connect your computer to the NXC (the default IP address is https://192.168.1.1) and access its web configurator. See the NXC Series User's Guide for more information.
Note: If they are in different networks, the WAC6552D-S stays in standalone AP mode. Go to the next section to access the WAC6552D-S and see the NWA/WAC Series User's Guide for how to configure its AC Discovery settings so that the WAC6552D-S can be managed by the controller.
![Zyxel - WAC6552D-S - Managed AP Mode Managed AP Mode]()
Standalone AP Mode (Option 2)
- From a Wi-Fi enabled computer, search for the WAC6552D-S's default Wi-Fi network name (Zyxel) and connect to it.
![Zyxel - WAC6552D-S - Using the Standalone AP Mode - Step 1 Using the Standalone AP Mode - Step 1]()
- Open your web browser and enter "http://1.1.1.1" for initial configuration. Enter the default user name (admin) and password (1234). Click Login.
Note: If your computer doesn't have a Wi-Fi adapter, use an Ethernet cable to connect your computer to the WAC6552D-S or the router. Use its DHCP-assigned IP or default static IP address (192.168.1.2) to access the web configurator. Make sure your computer IP address is in the same subnet as the WAC6552D-S's.
![Zyxel - WAC6552D-S - Using the Standalone AP Mode - Step 2 Using the Standalone AP Mode - Step 2]()
Management IP Address: | Connect UPLINK to Router | DHCP-assigned |
Not Connect UPLINK to Router | 192.168.1.2 |
SSID: | Zyxel |
Wi-Fi Security | Disabled |
- The wizard appears automatically. Use the wizard to set up your WAC6552D-S
Note: It takes 1 to 2 minutes to apply your wizard changes. Check the Dashboard screen and note down the WAC6552D-S's IP address in case you need to access it's web configurator again.
Note: The 1.1.1.1 is for initial setup only. It is not usable after the WAC6552D-S is configured.
![Zyxel - WAC6552D-S - Using the Standalone AP Mode - Step 3 Using the Standalone AP Mode - Step 3]()
- Use the WAC6552D-S's new wireless settings (SSID and key) to re-connect to the WAC6552D-S's Wi-Fi network for Internet access if you change them in the wizard.
![Zyxel - WAC6552D-S - Using the Standalone AP Mode - Step 4 Using the Standalone AP Mode - Step 4]()
Pole Mounting
- Attach the rotating bracket to the mounting main frame using spacers, washers and nuts.
Note: Do not tighten the nuts until after you mount the WAC6552D-S to a pole and adjust the mounting angle.
![Zyxel - WAC6552D-S - Pole Mounting - Step 1 Pole Mounting - Step 1]()
- Align the holes on the M-type bracket with the screws on the inner case. Attach them using spacers, washers and nuts.
![Zyxel - WAC6552D-S - Pole Mounting - Step 2 Pole Mounting - Step 2]()
- Align the rotating bracket's holes with the holes on the M-type bracket.
Insert the steel tube through the holes, and use washers and nuts to secure it.
![Zyxel - WAC6552D-S - Pole Mounting - Step 3 Pole Mounting - Step 3]()
- Place the metal belts around a pole, and insert them into the holes on the mounting main frame. Use a wrench to tighten the nuts and secure the WAC6552D-S.
Adjust the angle so that the WAC6552D-S is encompassing the desired coverage area.
Note: It is recommended the WAC6552D-S should not exceed a +15 or -15 degree angle relative to the pole.
Note: The pole diameter cannot exceed 6.35 cm.
![Zyxel - WAC6552D-S - Pole Mounting - Step 4 Pole Mounting - Step 4]()
Grounding
To help protect against lightning and interference functions, secure a green/yellow ground cable (18 AWG or smaller) to the WAC6552D-S.
![Zyxel - WAC6552D-S - Grounding Grounding]()
North America USA
+ 1 800 255 4101
support@zyxel.com
UK
+ 44 (0) 118 912 1700
support@zyxel.co.uk
France
+33 (0) 892 692 610
support@zyxel.fr
Spain
+ 34 911 792 100
soporte@zyxel.es
EU Importer
Zyxel Communications A/S
Gladsaxevej 378, 2. th. 2860 Søborg, Denmark
http://www.zyxel.dk
US Importer
Zyxel Communications, Inc
1130 North Miller Street Anaheim, CA 92806-2001
http://www.us.zyxel.com
Copyright © 2018 Zyxel Communications Corp. All Rights Reserved.
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Zyxel WAC6552D-S - 802.11 Ac Unified Pro Outdoor Access Point Quick Start Guide
Need help?
Do you have a question about the WAC6552D-S and is the answer not in the manual?
Questions and answers