SUN2000 Smart PV Optimizer
User Manual
Output
Technical
Specifications
Rated output power
Output voltage
Maximum output
current
Output bypass
Shutdown output
voltage/impedance
General Specifications
Technical
Specifications
Dimensions (H x W
x D)
Net weight
DC input and
output terminals
Operating
a
temperature
Storage
temperature
Operating humidity
Maximum
operating altitude
IP rating
Installation mode
Note a: When the operating temperature of the optimizer ranges from 70°C to 85°C, the
optimizer may shut down for overtemperature protection and report an overtemperature alarm.
After the operating temperature decreases, the optimizer automatically recovers with no risk of
damage.
Issue 04 (2023-04-21)
SUN2000-450W-P
450 W
4–80 V
15 A
Yes
0 V/1 kΩ (±10%)
SUN2000-450W-P
138 mm x 71 mm x 25 mm
≤ 550 g
Staubli MC4
–40°C to +85°C
–40°C to +70°C
0–100% RH
4000 m
IP68
● PV module support installation
● PV module frame installation
Copyright © Huawei Digital Power Technologies Co., Ltd.
3 Technical Specifications
21