Swytch eBike Conversion Kit Instruction Manual page 49

Table of Contents

Advertisement

1.
Error Codes - Base Display
1.1
These are some of the most
common error codes you may
encounter when using the base
display.
Error
Lights
Code
21
Flash at PAS
Level 1
23
Flash at PAS
Level 3 & 5
24
Flash at PAS
Level 5
25
Flash at PAS
Level 3 & 5
30
Flash at all
levels and
both PAS
and Battery
Troubleshooting
Problem
Motor current abnormality
Motor phase abnormality
Motor hall signal abnormality
Brake abnormality
(commonly happens when
brakes are engaged before
the Power Pack is turned on)
Communication abnormality
(Controller and Display aren't
connected)
49
Action Required
Contact customer service
Contact customer service
Contact customer service
Remove the Power Pack then
either:
- disconnect the brake sensors,
reattach turn on the Power
Pack, then reconnect the brake
sensors
- or, turn off the Power Pack,
ensure the brakes are released,
then turn the Power Pack back
on
Check the display is connected
to the mount