Nalco 3D TRASAR Series Installation And Operation Manual page 208

Table of Contents

Advertisement

Replacement Parts / Reagents and Calibration Supplies
Part Number
500-TSRKITSTR.88
3500 Series Calibration Start-up Kit includes 3D TRASAR Calibration Solution 1L (2),
Fluorometer Cleaning Solution 1L, Fluorometer Probe Brush, 500 mL Plastic Beakers (3), 60 cc
Plastic Syringes (3)
500-TSRKIT.88
5500 Series Calibration Start-up Kit includes 3D TRASAR Calibration Solution 1L (2), pH
7.0 and 10.0 Calibration Solutions 1L (1 of each), ORP 200 mv and 600 mv Calibration
Solutions 1L (1 of each), Fluorometer Cleaning Solution 1L, Replacement Mild Steel and
Copper NCM Probes (1 of each), Fluorometer Probe Brush, 500 mL Plastic Beakers (3), 60 cc
Plastic Syringes (3)
060-TRMNKIT.88
Maintenance Value Package includes 3D TRASAR Calibration Solution 1L (2), pH 7.0 and
10.0 Calibration Solutions 1L (1 of each), ORP 200 mv and 600 mv Calibration Solutions 1L
(1of each), Fluorometer C leaning Solution 1L, Fluorometer Probe Brush, 500 mL Plastic
Beakers (3), 60 cc Plastic Syringes (3), Replacement pH Probe (1), Replacement ORP Probe
(1), Replacement Mild Steel and Copper NCM Probes (2 of each), Fluorometer D essicant
Canister, Fluorometer Dessicant Indicator
460-S0940.75
460-S0408.75
460-S0407.75
460-S0932A.75
460-S0933A.75
460-S0800.75
460-S0726.75*
500-P2817.88
500-P0116.88
500-P2147.88
460-3DTBRC.87*
460-S0298.75*
460-S0297.75*
* This part is available as an optional accessory, but is not included with either the Start-up
Kit or the Maintenance Value Package.
Technical Help
(630) 305-CHEM
3D TRASAR 3500 Series Calibration Start-up Kit
3D TRASAR 5000 Series Calibration Start-up Kit
3D TRASAR 5000 Series Maintenance Value Package
3D TRASAR Calibration Solution, 1L
pH Calibration Solution, pH 10.0, 1L
pH Calibration Solution, pH 7.0, 1L
ORP Calibration Solution, 200 mv, 1L
ORP Calibration Solution, 600 mv, 1L
Fluorometer Cleaning Solution, 1L (Sulfuric Acid 10%)
Fluorometer Cleaning Solution, 1L (HCl 1:1)
Flow Cell Brush
Beaker, 500 mL, plastic
Syringe, 60 cc, w/ female lu er lock, plastic
Bio-reporter Quick Dose Pouch (pretreats approx. 150,000 gallons)
Conductivity C alibration Solution, 600 uS, 1L
Conductivity C alibration Solution, 3000 uS, 1L
521-OM0108.88
Copyright © 2009 Nalco Company
®
3D TRASAR
5500 - Installation & Operation Manual
Description
C-5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3D TRASAR Series and is the answer not in the manual?

Questions and answers

aweh maxwell philips
February 22, 2025

dcs operator is not getting a signal from the field

1 comments:
Mr. Anderson
February 22, 2025

Check the following:
1. Ensure the conductivity or fluorometer sensor connections are secure in the controller.
2. Replace the sensor cable if damaged.
3. Power off and on to reset the system.
4. Verify ISP settings (username, password, access phone number).
5. Confirm the controller is registered with 3D TRASAR Web.
6. If using a GSM/GPRS connection, check signal strength and consider using a high-gain antenna if necessary.

This answer is automatically generated

Brandon Whitten
March 21, 2025

How do I switch 4-20ma output AO5 Port right now its sending 4ma out for 100% of span and 20ma out for 0%. I Would like to switch it to 4ma 0% and 20ma 100% of span so if it looses power out bleach pump does not continuously run.

1 comments:
Mr. Anderson
March 21, 2025

The provided context does not include specific steps for configuring the 4-20mA output on the Nalco 3D TRASAR Series. However, based on standard practices, configuring the 4-20mA output typically involves accessing the controller’s settings through its interface or software and adjusting the output scaling. You would set the lower range (0%) to output 4mA and the upper range (100%) to output 20mA. If the controller has a calibration or configuration menu, navigate to the analog output settings and enter the desired span values accordingly.

If further details are required, refer to the controller’s installation and operation manual.

This answer is automatically generated

Table of Contents

Save PDF