Additional Checks
10. Raise the boom above 40°. Stabil-Trak system locked mode will be activated and
indicator will illuminate.
11. Lower boom below 40°.
12. Shift transmission to neutral.
8.2
BOOM/OUTRIGGER INTERLOCK (10054 & 12054)
Boom/Outrigger Interlock System Test
Boom/Outrigger Interlock system operates in two modes. In extend interlock mode,
with outriggers raised, a sensor in the boom will stop boom from extending past a point
between the "E" and "F" extension indicators. In outrigger interlock mode, with
outriggers lowered, boom will extend fully and Stabil-Trak indicator will illuminate. To
check the sensor and indicator, perform the following:
8
7
1. Test Boom/Outrigger Interlock system on a level surface and boom horizontal, no
load.
2. Shift transmission to neutral (6) and engage park brake (3).
3. Raise outriggers (9).
4. Extend boom until it stops. Boom will stop at a point (8) between the "E" and "F"
extension indicators.