All electrical installation must be carried out by an approved electrician in accordance with Part "P" U.K. Building Regulations and to the latest IET standards, or the appropriate regulations in the country of installation.
The iCONsmart 15 requires a 110V—240V 50/60 Hz single phase supply.
The iCONsmart 15 is IPX5 rated and therefore it is suitable for mounting in bathrooms (in zone 1 and 2).
For fans mounted in zones 1 & 2 as defined in BS 7671:2018, additional protection must be provided by a Residual Current Device (RCD) not exceeding 30mA as well as having an Arc Fault Detection Device (AFDD).
A disconnector (e.g. Isolator switch, circuit breaker) with a distance greater than 3 mm between its open contacts shall be required according to BS 60669-1.
Switches for fans should be selected and sited in accordance with BS 7671:2018.
Model | A | B | C | D | E |
iCONsmart 15 | 194 | 118 | 100 | 72 | 144 |
iCONsmart comes with a newly developed flow sensing technology that automatically adjusts and maintains the set extraction flow rates when within the parameters of the fan.
iCONsmart has several features included as standard and can also be fitted with digital micro modules to give a range of extra control options.
These include: timer module (TM) functionality that can be unlocked via a unique code (on a scratch card), humidity & timer (HT), motion sensor & timer (MST) or a combination of all three (MSHT). These modules are available separately and can be fitted at the time of installation or retro-fitted.
(If you have purchased a module for installation, refer to module instructions now.)
The iCONsmart can be installed into a wall or ceiling. When fitting fans in the ceiling, if high density plasterboard is not used, a support (min 18mm thick) should be mounted between the ceiling joists. Fans should not be fitted to unsupported plasterboards. (Fig. 3)
When the iCONsmart is first powered on, you will hear the initial reset for 10-15 seconds. This is normal and will also occur if the fan is in its reset mode.
To activate the iCONsmart and to set it up:
Individual installation instructions are supplied with each module.
Ensure that flexible duct connections are not over tightened to the spigots. To maximise the air flow, rigid ducting should be used where possible. The fan and ducting should be installed in accordance with the requirements of the Domestic Ventilation Compliance Guide, part of Part F of the Building Regulations.
Where flexible ducting is used ensure it is pulled to 90% of its full length.
Home — From this page you can activate the fan, as well as viewing and adjusting the flow rate.
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE DOING ANY WORK ON THE FAN / MODULE.
When installed by a competent installer according to user instructions, the iCONsmart range is completely safe. The materials used in its construction do not constitute a hazard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or fully instructed concerning the use of the appliance by a person responsible for their safety.
Fan and ducting should be inspected and cleaned on a regular basis to maintain fan performance. The external housing of the fan can be wiped with a damp cloth.
Do not use household cleaners containing abrasives. Cleaning of the internal parts such as the impeller should be carried out by using a soft brush. Never clean any parts of the fan assembly by immersing in water or using a dishwasher.
Settings — Contains all adjustable settings from the setup and more: Setting the flow rates, fan name, unlock timer functionality and all module parameters.
Usage Data — The iCONsmart can store up to 3 months rolling log of power use, time-on, flow rates, temperature and humidity levels (Requires the humidity module to be installed and connected to view temperature and humidity levels log).
Airflow guarantees the iCONsmart and iCONsmart modules for 5 years from date of purchase against faulty material or workmanship. Applicable to units installed and used in the UNITED KINGDOM.
Warranty covers the fan, not the reinstallation of this if required.
iCONsmart has been CB tested and FCC certified to demonstrate the thoughtful engineering behind the fan design. It has been awarded the TUV certification for its safety, functionality and quality.
Do not place the fan near any direct heat sources, e.g. radiant heaters, or where the ambient temperature can exceed 40°C (104°F).
To avoid the backflow of condensation into the fan in ceiling installations Airflow recommends fitting a condensation trap to the outlet duct of the fan.
Where flexible ducting is used the diameter must be maintained and it is good ventilation practice that the ducting is extended to a minimum of 90% of its possible length in order to maintain the best possible air flow.
Airflow Developments Ltd shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence. Full details at airflow.com/terms
This warranty does not in any way affect any statutory or other consumer rights.
Do not dispose of with household waste.
Please recycle where facilities exist.
Check with your local authority for recycling advice.