Page 1
E M E R G E N C Y C O M M U N I C A T I O N S Installation & Operations Manual Emergency Call Station 2100-CPV Series RP8500CPV N56 W24720 N. Corporate Circle Sussex, WI 53089 Version 1 Made in the USA 866-850-8854 262-246-4828 (fax) www.rathsecurity.com...
Page 2
Thank you for purchasing the Rath Emergency Call Stations. We take great pride in our products, service and support. Our #1 mission is customer satisfaction. When evaluating emergency communication systems, you can rely on Rath to continually provide Innovative Thinking, Design and Value.
Page 3
4. 120 AC to DC Transformer Call Station Installation: Rath recommends that the call station be mounted so that the push button is less than 48 inches above the ground to comply with the Americans with Disabilities (ADA) requirements. For ease of installation, two people should perform the install.
Page 4
Wiring Diagram Enter Record Play / Pause Stop Annunciator Audio Connector To Constant Strobe Pair of wires Pair of wires for Strobe for Camera 10 conductor cable to front plate Wago Connector 10 contact Water proof wire nuts for Ground Hot, Neutral, and Ground Phone line connect with...
Page 5
Programming the Phone: *Note: Programming not required if customer information provided to the factory - Proceed to Testing 1. You can program the phone on-site or program remotely. 2. If programming on-site, open up back access panel located directly behind front stainless steel face plate.
Page 6
Reinstall the cover on the NEMA enclosure and secure the rear access panel. Suggested Ongoing Testing of the Phone: Rath recommends that the Emergency call stations be tested and maintained on a monthly basis to ensure proper operation. For testing, follow the procedure outlined in Testing of the Phone.
Page 7
Troubleshooting: Problem Possible Cause & Fixes • Check to make sure the phone line connected. No dial tone when the button is pushed: • Speaker control needs to be adjusted. Go to Speaker Adjustment on page 5. Audio is low from the speaker: •...
Page 8
Model: 2100-CPV Emergency Tower Dimensional Specifications: Call Station Body of Tower: Height 36 in. Width 10 in. Depth 8 in. Thickness of Steel 18 gauge Weight 51 lbs. pg. 7 E M E R G E N C Y C O M M U N I C A T I O N S 866-850-8854 www.rathsecurity.com...
Page 9
This Warranty statement of policy is in lieu of any other policy expressed or implied and no representative or person is authorized to assume any other liability or adopt any other policy for Rath without our written consent.
Need help?
Do you have a question about the 2100-CPV Series and is the answer not in the manual?
Questions and answers