Error Codes
The following are common error codes and solutions.
Error Code
Error
Error 1
Motor phase wire fault
Error 2
Motor hall sensor fault
Error 3
Throttle fault
Error 4
Under voltage fault
Error 5
Controller fault
Error 6
Instrument fault
Error 7
Over temperature fault
Solution
Check motor phase wires from the motor axle all the
way to the controller. Check that there are no exposed,
loose or damaged connections or cabling.
Check motor hall sensor wires from the motor axle all
the way to the controller. Check that there are no
exposed, loose or damaged connections or cabling.
Check the throttle cable for a loose connection or
damage and see if the error goes away. If not, the
sensor box may be faulty and need replacement.
Check the battery voltage and the system settings to
ensure they are set correctly. If it is below working
voltage range, you may receive this error.
Check the display to determine which controller is
faulty. Will likely require replacement.
Check if the TFT display, button console, cables and
connections are not damaged and seated correctly.
Immediately stop using the scooter and let it cool for
awhile until the error subsides. This is a temperature
over-protection feature to ensure the scooter doesn't
get too hot.
Distributed by and property of VoroMotors
12
Need help?
Do you have a question about the EMOVE RoadRunner Pro and is the answer not in the manual?